Magellan / Spectra SP
35
System Programming
[700]
General System Options
Bold
= Default setting
Option
OFF
ON
[1]
Partitioning
N
Disabled
N
Enabled
[2]
Battery charging (350mA or 700mA)
N
350mA
N
700mA
[3]
Audible trouble warning (except AC failure)
N
Disabled
N
Enabled
[4]
Audible trouble warning on AC failure
N
Disabled
N
Enabled
[5]
RF jamming supervision
N
Disabled
N
Enabled
[6]
Exit delay termination
N
Disabled
N
Enabled
[7]
Tamper supervision on the bus module
N
Disabled
N
Enabled
[8]
N/A
N/A
N/A
[701]
General Code Options
Bold
= Default setting
Option
OFF
ON
[1]
Access code length
N
6 digits
N
4 digits
[2]
Lock master code
N
Disabled
N
Enabled
[3]
Confidential mode
N
Disabled
N
Enabled
[4]
To exit confidential mode
N
Enter a code
N
Press a key
[5]
Confidential mode timer
N
2 minutes
N
5 seconds
[6]
MG-REM2 version number
N
MG-REM2 V2.00
N
MG-REM2 V2.01
or
higher
[7]
Display entry delay on LCD keypad (MG32LCD)
N
Disabled
N
Enabled
[8]
Display exit delay on LCD keypad (MG32LCD)
N
Disabled
N
Enabled
[702]
Panic Options
Bold
= Default setting
Option
OFF
ON
[1]
Panic 1
N
Disabled
N
Enabled
[2]
Panic 2
N
Disabled
N
Enabled
[3]
Panic 3
N
Disabled
N
Enabled
[4]
Panic 1: Silent or audible alarm
N
Silent
N
Audible
[5]
Panic 2: Silent or audible alarm
N
Silent
N
Audible
[6]
Panic 3: Silent or audible alarm
N
Silent
N
Audible
[7] & [8]
N/A
N/A
N/A
[703]
Arming/Disarming Options 1
Bold
= Default setting
Option
OFF
ON
[1]
One-touch regular/force arming
N
Disabled
N
Enabled
[2]
One-touch stay arming
N
Disabled
N
Enabled
[3]
One-touch sleep arming
N
Disabled
N
Enabled
[4]
One-touch bypass programming
N
Disabled
N
Enabled
[5]
Restrict arming on battery failure
N
Disabled
N
Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
N
Disabled
N
Enabled
[7]
Restrict arming on wireless supervision trouble (Zone + Bus
Wireless PGM)
N
Disabled
N
Enabled
[8]
Arm/Disarm with VDMP3
N
Disabled
N
Enabled
Summary of Contents for SP5500