Zone Programming
For keypad zone programming, see page 16.
Zone Definitions
Stay Arm
Sleep Arm
Fully Arm
Zone Definitions
01
= Entry Delay 1
Entry Delay 1
Entry Delay 1
Entry Delay 1
11
= Instant Fire†
02
= Entry Delay 2
Entry Delay 2
Entry Delay 2
Entry Delay 2
12
= Delayed Fire†
03
= Entry Delay 1 (Full Arm)
Not Armed
Not Armed
Entry Delay 1
13
= Instant Fire Silent†
04
= Entry Delay2 (Full Arm)
Not Armed
Not Armed
Entry Delay 2
14
= Delayed Fire Silent†
05
= Follow
Follow
*
Follow
*
Follow
*
15
= 24Hr. Buzzer
06
= Follow (Sleep/Full Arm)
Not Armed
Follow
*
Follow
16
= 24Hr. Burglary
07
= Follow (Full Arm)
Not Armed
Not Armed
Follow
17
= 24Hr. Hold-up
08
= Instant
Instant
*
Instant
*
Instant
*
18
= 24Hr. Gas
09
= Instant (Sleep/Full Arm)
Not Armed
Instant
*
Instant
19
= 24Hr. Heat
10
= Instant (Full Arm)
Not Armed
Not Armed
Instant
20
= 24Hr. Water
21
= 24Hr. Freeze
22
= 24hr. Panic
23
= Instant No Pre-Alarm
* Flex-Instant = Zone will follow the delay at section [720], (default is 15 seconds / 0 = instant zone)
24
= Follow No Pre-Alarm
** On-board hardwire control panel zones only
25
= Keyswitch Maintain**
† APR-ZX8 inputs do not support fire zones.
For 2-wire smoke installations (not supported by SP5500), these definitions apply to Zone 1 Input
only. Section
[705]
, option
[3]
must be enabled.
For 4-wire smoke installations, use any panel on-board zone input.
26
= Keyswitch Momentary**
Keyswitch Options (25-26)
[1]- N/A
[2]- N/A
[3]- N/A
[4]
OFF = Disarm
ON = Disarm only if Stay/
Sleep armed
[5] = Arm only
[6] = Stay arming*
[7] = Sleep arming*
[8] = N/A
* Select only one. If all are off,
keyswitch will regular arm.
Partition Assignment
[1]- Partition 1
[2]- Partition 2
[3]- Both partitions
Zone Options
[1] = Auto-zone Shutdown
[2] = Bypassable Zone
[3]
=
RF Supervision
[4] [5]
OFF OFF Audible Alarm
OFF ON Pulsed Alarm
ON OFF Silent Alarm
ON ON Report Only
[6] = Intellizone
[7] = Delay alarm transmission
[8] = Force Zone
Summary of Contents for SP5500
Page 51: ...Magellan Spectra SP 51 Hardware Connections Single Zone Inputs...
Page 52: ...52 Programming Guide Advanced Technology Zone ATZ Connections...
Page 56: ...56 Programming Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Page 63: ......
Page 64: ...paradox com Printed in Canada 07 2007 MGSP EP11...