Magellan / Spectra SP
39
Communication Programming
[800] Dialer Options
Bold
= Default setting
Option
OFF
ON
[1] & [2]
N
See Table
N
See Table
[3]
Switch to pulse on 5
th
attempt
N
Disabled
N
Enabled
[4]
Alternate dial
N
Disabled
N
Enabled
[5]
Force dial (must be enabled to comply with TBR-21)
N
Disabled
N
Enabled
[6]
DTMF dialing
N
Disabled
N
Enabled
[7]
Pulse ratio
N
1:2
N
1:1.5
[8]
Disable test reporting
N
Disabled
N
Enabled
[801] Dialer Options
Bold
= Default setting
Option
OFF
ON
[1]
Report system disarming
N
Always
N
After alarm
[2]
Report zone restore
N
Bell cutoff
N
Zone closure
[3]
&
[4]
[5]
to
[8]
N/A
N/A
N/A
[802] Event Call Direction Options 1
Bold
= Default setting
Option
OFF
ON
[1]
Call tel. #1 for arm/disarm reporting codes
N
Disabled
N
Enabled
[2]
Call tel. #2 for arm/disarm reporting codes
N
Disabled
N
Enabled
[3]
Call pager for arm/disarm reporting codes
N
Disabled
N
Enabled
[4]
N/A
N/A
N/A
[5]
Call tel. #1 for alarm/restore reporting codes
N
Disabled
N
Enabled
[6]
Call tel. #2 for alarm/restore reporting codes
N
Disabled
N
Enabled
[7]
Call pager for alarm/restore reporting codes
N
Disabled
N
Enabled
[8]
N/A
N/A
N/A
Telephone
Line Monitoring (TLM)
Options
[1]
[2]
OFF
OFF
Disabled
OFF
ON
When disarmed: Trouble only
When armed: Trouble only
ON
OFF
When disarmed: Trouble only
When armed: Audible alarm
ON
ON
Silent alarms become Audible alarm
[3]
[4]
Auto-Test Report Transmission Options
OFF
OFF
Transmit the test report code every time the days programmed in section
[840]
have elapsed at the time programmed in
section
[850]
(default).
OFF
ON
When disarmed: Transmit test report code every time the time programmed in section
[852]
has elapsed. When armed:
Transmit test report code every time the time programmed in section
[851]
has elapsed.
ON
OFF The control panel will transmit the test report code every hour on the minute value programmed in section
[850]
(the last
two digits). Note that the first two digits of section
[850]
will be ignored.
E.g. If 10:25 was programmed into section [850],
the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON
ON
The test report code will be transmitted when any of the conditions of the second and third options listed above (options
[3]
= OFF and
[4]
= ON / options
[3]
= ON and
[4]
= OFF) are met.
Summary of Contents for SP5500
Page 51: ...Magellan Spectra SP 51 Hardware Connections Single Zone Inputs...
Page 52: ...52 Programming Guide Advanced Technology Zone ATZ Connections...
Page 56: ...56 Programming Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Page 63: ......
Page 64: ...paradox com Printed in Canada 07 2007 MGSP EP11...