48
Programming Guide
Auxiliary supply trouble restore
3 3AA - System trouble restore
YQ - Power supply restored
Bell output current limit restore
3 321 - Bell 1 restore
YH - Bell restored
Bell absent restore
3 321 - Bell 1 restore
YH - Bell restored
Clock programmed
3 625 - Time/date reset
JT - Time changed
Fire loop trouble restore
3 373 - Fire trouble restore
FJ - Fire trouble restore
Fail to communicate with monitoring station
3 354 - Fail to communicate
YK - Communication fails
RF interference
3 344 - RF receiver jam detection
XH - RF Interference Restoral
Combus fault
1 333 - Expansion module failure
ET - Expansion trouble
Module tamper
1 341 - Expansion module tamper
TA - Tamper alarm
Bus fault restore
3 333 - Expansion module failure restore
ER - Expansion restoral
Module tamper restore
3 341 - Expansion module tamper restore
TR - Tamper restoral
Cold start
1 3A8 - System shutdown
RR - Power up
Test report engaged
1 6A2 - Periodic test report
TX - Test report
PC software communication finished
1 412 - Successful - download access
RS - Remote program success
Installer on site
1 627 - Program mode entry
LB - Local program
Installer programming finished
1 628 - Program mode exit
LS - Local program success
Maintenance in
1 627 - Program mode entry
LB - Local program
Maintenance out
1 628 - Program mode exit
LS - Local program success
Closing delinquency
1 654 - System inactivity
CD - System inactivity
Module AC fail
1 342 - AC failure on module
AT - Module AC fail
Module AC fail restore
3 342 - AC restored on module
AR - Module AC fail restore
Module battery fail
1 338 - Battery failure on module
YT - Module battery fail
Module battery fail restore
3 338 - Battery failure on module
YR - Module battery fail restore
RF Module low battery
1 384 - RF transmitter low battery
XT - Transmitter battery trouble
RF Module battery restore
3 384 - RF transmitter battery restore
XR - Transmitter battery restoral
RF Module supervision trouble
1 381 - Loss of supervision - RF
US - Untype zone supervision
RF Module supervision restore
3 381 - Supervision restore - RF
UR - Untyped zone restoral
RF Module supervision lost
1 381 - Loss of supervision- RF
US - Untyped Zone Supervisory
RF Module supervision restore
3 381 - Loss of supervision- RF restore
UR - Untyped Zone Restoral
RF Module tamper
1 145 - Expansion module tamper
ES - Expansion Device Tamper
RF Module tamper restore
3 145 - Expansion module tamper restore
EJ - Expansion Device Restore
Paramedic alarm
1 1AA - Medical
MA - Medical Alarm
Zone forced
1 57A - Zone forced
XW - Zone forced
Zone included
3 57A - Zone included
UU - Zone included
System Event
Default Contact ID Report Code
Default SIA Report Code
Summary of Contents for SP5500
Page 51: ...Magellan Spectra SP 51 Hardware Connections Single Zone Inputs...
Page 52: ...52 Programming Guide Advanced Technology Zone ATZ Connections...
Page 56: ...56 Programming Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Page 63: ......
Page 64: ...paradox com Printed in Canada 07 2007 MGSP EP11...