Digiplex LCD Keypad 29
n
6.5.2 Door Left Open Interval Before Access Alarm
Section [008]
The Door Left Open Interval is the time that a door can remain
open after an Access Granted or a Request for Exit without
generating an Access Alarm. Enter any value between 001 and
255 to determine the number of seconds the door may remain
open before the Access Alarm is triggered. (default = 60
seconds)
6.5.3 Door Left Open Pre-Alarm
Section [003]: Option [3]
An Access Control door is programmed with a Door Left Open
Interval (see section 6.5.2 above). The Pre-Alarm will cause the
reader to beep a certain time before the end of the Door Left
Open Interval to alert users that the Access Control door was left
open and will generate an Access Alarm if it is not closed. The
Pre-Alarm beeps slower than the Door Left Open Alarm (about
twice every second). Program the Pre-Alarm timer in section
[009]
.
Option
[3]
ON = Pre-Alarm is enabled. (default)
Option
[3]
OFF= The Pre-Alarm will not be generated.
6.5.4 Door Left Open Pre-Alarm Timer
Section [009]
This timer will trigger the Door Left Open Pre-Alarm before the
end of the Door Left Open Interval (see section 6.5.3 above). For
example, if 60 seconds is programmed in section
[008]
and 15
seconds is programmed in section
[009]
, then 60 minus 15 is 45.
Therefore, the reader will start beeping after the door has been
Summary of Contents for Digiplex DGP-641
Page 2: ......
Page 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Page 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Page 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Page 42: ......
Page 43: ......
Page 44: ......