26 Installer’s Guide
6.4.3 Door Unlocked Period Extension
Section [007]
The Door Unlocked Period Extension is the amount of time
added to the Door Unlocked Period in section
[006]
, which
leaves the door unlatched longer. This will allow those with this
feature enabled on their User Access Codes extra time to enter,
which may be useful for the physically challenged or for seniors.
Enter any value between 001 and 255 to determine the number
of seconds to be added to the time programmed in section
[006]
.
(default = 15 seconds)
6.4.4 Relock Interval
Section [005]: Option [6]
The locking device will remain unlatched during the Door
Unlocked Period (see section 6.4.2 on page 25), but once the
door is opened it can be programmed to latch as soon as the
door closes or latch immediately even if the door has not closed.
Option
[6]
ON = Locking device latches when door closes
Option
[6]
OFF= Locking device latches immediately. (default)
6.4.5 Door Unlocked Schedule
Section [012]
The Door Unlocked Schedule determines the hours, days, and
holidays that the door will remain unlocked. Therefore, users will
not have to present their Access Control Cards to the reader in
order to gain access to an Access Control Door during the Door
Unlocked Schedule. The schedule consists of two programmable
time periods called “Intervals” that determine the time of day and
which days the users will be granted access. When a schedule is
Summary of Contents for Digiplex DGP-641