background image

English, Français, Español, Português

NOTE:  Refer to the System Installation Manual for information on limitations regarding product use and function, and information on the limitations as to liability of the manu-

facturer.

NOTE: These instructions shall be used with the appropriate Control Panel Installation Manual with which this equipment is intended to be used. Operating Instructions shall

be made available to the user.

NOTE: This Installation Sheet applies to the following models: HS2LCDWF, HS2LCDWFP, and HS2LCDWFPV.

NOTE: Do not dispose of the waste battery as unsorted municipal waste. Consult your local rules and/or laws regarding recycling of this battery; it will help protect the environ-

ment.

HS2LCDWF v1.0

 

Installation Instructions/Instructions d’Installation/Instrucciones de instalación/

Instruções de Instalação

Summary of Contents for HS2LCDWF v1.0

Page 1: ...ual with which this equipment is intended to be used Operating Instructions shall be made available to the user NOTE This Installation Sheet applies to the following models HS2LCDWF HS2LCDWFP and HS2LCDWFPV NOTE Do not dispose of the waste battery as unsorted municipal waste Consult your local rules and or laws regarding recycling of this battery it will help protect the environ ment HS2LCDWF v1 0...

Page 2: ... directed on the back of the keypad Ensure the correct polarity is observed 3 Replace the keypad on the mounting plate desk stand Installation Instructions Temperature range 10 C to 55 C 14 F to 131 F UL ULC 0 C to 49 C 32 F to 120 F Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 Power adaptor output voltage 9 0VDC 1 25A Mod els US Latin America xx Canada xx EU xx...

Page 3: ...is wired to the alarm panel and power has been applied power up a wireless keypad 2 Press any button on the keypad to enroll it on the HSM2HOST The HSM2HOST is then automatically enrolled on the alarm panel Enrolling Keypad 1 Enter 8 Installer Code and then section 804 000 2 When prompted either activate the device to enroll immediately or enter a device serial num ber Do the latter to pre enroll ...

Page 4: ...and select the label to change e g 8 Installer Code 000 001 to program the label for zone 01 2 Press to open the Select Options menu 3 Press again to select the Words option 4 Enter the 3 digit number corresponding to a word see Words table below or use the scroll keys to view words in the library 5 Press to select the word 6 To add another word repeat the above procedure from step 2 7 To add a sp...

Page 5: ...lost or no longer needed 1 Enter 5 and an access code with the supervisor attribute enabled 2 The keypad will display the user number and include the letter T if a prox tag is programmed 3 Scroll to Press for Prox Tag and press the key 4 The keypad will read Press To Delete Tag 5 After pressing the message Tag Deleted Successfully appears NOTE User codes can only be deleted individually NOTE User ...

Page 6: ...ommand Output 4 07 System Test 25 28 For Future Use 08 For Future Use 29 Bypass Group Recall 09 Night Arm 30 Quick Bypass 10 For Future Use 31 For Future Use 11 Away Arm no Entry 32 For Future Use 12 Global Stay Arm 33 Bypass Recall 13 Global Away Arm 34 For Future Use 14 Global Dis arming 35 For Future Use 15 For Future Use 36 Reactivate Stay Away and Night Zones Default Zone or PGM Number 00 I__...

Page 7: ...Hardware and Digital Security Controls a division of Tyco Safety Products Canada Ltd DSC the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the DSC software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy...

Page 8: ...RANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CH...

Page 9: ... X Armed Chime Duress Garage Level Office Right System A Y Arming Closed East Gas Library OK Room Tamper B Z Attic Closet Energy Glass Light On Safe Temperature C Space Auxiliary Closing Enter Goodbye Lights Open Saver Test D Apostrophe Away Code Entry Gym Living Opening Schedule Time E Dash Baby Communicator Error Hallway Load Panic Screen To F _ Underscore Back Computer Exercise Heat Loading Par...