CAUTION: Do not mix old batteries with new ones.

Apply AC Power

1. Slide the keypad up and out from the mounting

plate / desk stand.

2. Locate the power adaptor jack at the back of the

keypad housing.

3. Place the adaptor plug in the housing indentation,

perpendicular to the keypad. Insert the adaptor

plug firmly into the jack.

4. Pivot the adaptor plug downwards so that it fits

flush with the housing. Guide the AC wire along

the channel provided in the keypad housing; the

wire will extend through the bottom of the hous-

ing.

5. Replace the keypad on the mounting plate/desk

stand (in the latter case, a further channel is pro-

vided in the bottom of the desk stand. Guide the

AC wire along this channel; the wire will extend

through an opening in the back of the stand).

6. Plug the adaptor into a wall outlet.

NOTE: Only use the power adaptor (4.5VDC, 0.5A, 2.25W,

limited power supply model XX) supplied with the kit.

CAUTION: The socket-outlet in which the direct plug-in

adaptor is inserted must be close to the keypad, easily

accessible, and have unobstructed access. The plug of the

adaptor serves as a means of disconnection from the sup-

ply mains.

Programming the Keypad

There are several programming options available for

the keypad (see below). Programming the keypad is

similar to programming the rest of the system. To

turn an option on/off, press the number correspond-

ing to the option on the number pad. The numbers of

the options that are currently turned on will be dis-

played along the top of the LCD. For information on

programming the rest of your security system, please

refer to your system’s Installation Manual. 

Language Programming

To enter language programming, enter programming sec-

tion [000] then subsection [000]. Then enter the two-digit 

number that corresponds to the language desired: 

Enrolling the Keypad

The HSM2HOST wireless transceiver must be

enrolled onto the alarm panel before any wireless

devices can be enrolled.

When the alarm system is powered up for the first

time, the first keypad or the HSM2HOST (if using a

wireless keypad as the first keypad) can be enrolled.

To do this:

1. Once the HSM2HOST is wired to the alarm panel

and power has been applied, power up a wireless

keypad.

2. Press any button on the keypad to enroll it on the

HSM2HOST. The HSM2HOST is then automatically

enrolled on the alarm panel. 

Enrolling Keypad

1. Enter [

][8][Installer Code] and then section

[804] > 000.

2. When prompted, either activate the device to

enroll immediately or enter a device serial num-

ber. Do the latter to pre-enroll devices then enroll

them later at the customer site.

3. Use the scroll keys or type in the corresponding

number to select an option.

4.  Scroll through the available selections, key in a

number or enter text as appropriate.

5.  Press [*] to accept and move to the next option.

6. Once all options are configured, the system

prompts to enroll the next device.

7. Repeat the process described above until all wire-

less devices are enrolled.

Deleting Keypad

1. Enter [

][8][Installer Code] and then section

[804] > 905.

2. Use the scroll keys to select the keypad or press

[#] to exit. 

3. Select [*] to delete. The screen will read “Keypad

deleted”. 

Disassemble Keypad

1. Insert the tip of a flat-head screwdriver into the

slot at the bottom left section of the keypad. 

2. Gently lower the handle of the screwdriver, open-

ing the left side of the unit’s faceplate. 

3. Repeat steps 1 and 2 using the slot at the bottom-

right section of the unit. This will remove the

unit’s faceplate and allow access for mounting. 

Applying Battery Power

1. Slide the keypad up and out from the mounting

plate/desk stand (removing the screws first if

required). The bay for the four AA batteries is

open and visible at the back of the keypad.

2. Insert the batteries as directed on the back of the

keypad. Ensure the correct polarity is observed.

3. Replace the keypad on the mounting plate/desk

stand.

CAUTION: Do not mix old batteries with new ones.

Apply AC Power

1. Slide the keypad up and out from the mounting

plate/desk stand.

2. Locate the power adaptor jack at the back of the

keypad housing.

Plug

Mounting

Holes

Mounting

Holes

Wire

 channel

01 = English (default)

02 = Spanish

03 = Portuguese

04 = French

05 = Italian

06 = Dutch

07 = Polish

08 = Czech

09 = Finnish

10 = German

11 = Swedish

12 = Norwegian

13 = Danish

14 = Hebrew

15 = Greek

16 = Turkish

17 = FFU

18 = Croatian

19 = Hungarian

20 = Romanian

21 = Russian

22 = Bulgarian

23 = Latvian

24 = Lithuanian

25 = Ukrainian

26 = Slovakian

27 = Serbian

28 = Estonian

29 = Slovenian

Summary of Contents for HS2LCDWF v1.0

Page 1: ...ual with which this equipment is intended to be used Operating Instructions shall be made available to the user NOTE This Installation Sheet applies to the following models HS2LCDWF HS2LCDWFP and HS2LCDWFPV NOTE Do not dispose of the waste battery as unsorted municipal waste Consult your local rules and or laws regarding recycling of this battery it will help protect the environ ment HS2LCDWF v1 0...

Page 2: ... directed on the back of the keypad Ensure the correct polarity is observed 3 Replace the keypad on the mounting plate desk stand Installation Instructions Temperature range 10 C to 55 C 14 F to 131 F UL ULC 0 C to 49 C 32 F to 120 F Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 Power adaptor output voltage 9 0VDC 1 25A Mod els US Latin America xx Canada xx EU xx...

Page 3: ...is wired to the alarm panel and power has been applied power up a wireless keypad 2 Press any button on the keypad to enroll it on the HSM2HOST The HSM2HOST is then automatically enrolled on the alarm panel Enrolling Keypad 1 Enter 8 Installer Code and then section 804 000 2 When prompted either activate the device to enroll immediately or enter a device serial num ber Do the latter to pre enroll ...

Page 4: ...and select the label to change e g 8 Installer Code 000 001 to program the label for zone 01 2 Press to open the Select Options menu 3 Press again to select the Words option 4 Enter the 3 digit number corresponding to a word see Words table below or use the scroll keys to view words in the library 5 Press to select the word 6 To add another word repeat the above procedure from step 2 7 To add a sp...

Page 5: ...lost or no longer needed 1 Enter 5 and an access code with the supervisor attribute enabled 2 The keypad will display the user number and include the letter T if a prox tag is programmed 3 Scroll to Press for Prox Tag and press the key 4 The keypad will read Press To Delete Tag 5 After pressing the message Tag Deleted Successfully appears NOTE User codes can only be deleted individually NOTE User ...

Page 6: ...ommand Output 4 07 System Test 25 28 For Future Use 08 For Future Use 29 Bypass Group Recall 09 Night Arm 30 Quick Bypass 10 For Future Use 31 For Future Use 11 Away Arm no Entry 32 For Future Use 12 Global Stay Arm 33 Bypass Recall 13 Global Away Arm 34 For Future Use 14 Global Dis arming 35 For Future Use 15 For Future Use 36 Reactivate Stay Away and Night Zones Default Zone or PGM Number 00 I__...

Page 7: ...Hardware and Digital Security Controls a division of Tyco Safety Products Canada Ltd DSC the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the DSC software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy...

Page 8: ...RANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CH...

Page 9: ... X Armed Chime Duress Garage Level Office Right System A Y Arming Closed East Gas Library OK Room Tamper B Z Attic Closet Energy Glass Light On Safe Temperature C Space Auxiliary Closing Enter Goodbye Lights Open Saver Test D Apostrophe Away Code Entry Gym Living Opening Schedule Time E Dash Baby Communicator Error Hallway Load Panic Screen To F _ Underscore Back Computer Exercise Heat Loading Par...

Reviews: