background image

[023] Third Keypad Options

 

[030] LCD Message

[031] Downloaded LCD Message Duration 

Default: 000 

I_____I_____I_____I 

(Valid entries are 000-255), 000=Unlimited Message 

Display

This number represents the number of times the downloaded message must be

cleared before it is permanently removed. This message can be cleared by press-
ing any key.

[101]-[228] Door Chime for Zones 1-128

[999] Reset Keypad Programming to Factory Defaults

1. Enter Installer’s Code. 

2. Press [

] or 999.

Limited Warranty

 

Digital Security Controls (DSC) warrants that for a period of 12 months from the date of purchase, the product shall be free of

defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, DSC shall, at its

option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to

defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control

of DSC such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or

improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of

any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of DSC. DSC neither

assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor

to assume for it any other warranty or liability concerning this product. In no event shall DSC be liable for any direct, indirect or

consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the

purchase, installation or operation or failure of this product. 

WARNING: DSC recommends that the entire system be completely

tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disrup-

tion, it is possible for this product to fail to perform as expected. Important Information: Changes or modifications not expressly

approved by DSC could void the user’s authority to operate this equipment.

EN50131-1 Grade 2, Class 2, EN50131-6 Type B

Important Information

: Changes/modifications not expressly approved by DSC could void the user’s authority to operate this

equipment.
IMPORTANT - READ CAREFULLY: DSC Software purchased with or without Products and Components is copyrighted and is

purchased under the following license terms:

• This End-User License Agreement (“EULA”) is a legal agreement between 

You

 (the company, individual or entity who

acquired the Software and any related Hardware) and 

Digital Security Controls, a division of Tyco Safety Products Canada

Ltd.

 (“DSC”), the manufacturer of the integrated security systems and the developer of the software and any related products

or components (“HARDWARE”) which You acquired. 

• If the DSC software product (“SOFTWARE PRODUCT” or “SOFTWARE”) is intended to be accompanied by HARDWARE,

and is NOT accompanied by new HARDWARE, You may not use, copy or install the SOFTWARE PRODUCT. The SOFTWARE

PRODUCT includes computer software, and may include associated media, printed materials, and “online” or electronic doc-

umentation. 

• Any software provided along with the SOFTWARE PRODUCT that is associated with a separate end-user license agreement

is licensed to You under the terms of that license agreement. 

• By installing, copying, downloading, storing, accessing or otherwise using the SOFTWARE PRODUCT, You agree uncondi-

tionally to be bound by the terms of this EULA, even if this EULA is deemed to be a modification of any previous arrangement

or contract. If You do not agree to the terms of this EULA, DSC is unwilling to license the SOFTWARE PRODUCT to You, and

You have no right to use it.

SOFTWARE PRODUCT LICENSE

ON

I_____I

6

Power LED Indicates AC 

Present ON

Power LED Indicates 

AC Present OFF

ON

I_____I

7

Alarms Displayed While 

Armed 

Alarms Not Displayed 

While Armed 

OFF I_____I

8

Auto-Scroll Open Zones 

ON

Auto-Scroll Open 

Zones OFF

Default

Opt. ON

OFF

OFF  I____I 1

Armed LED On in 

Sleep Mode

Armed LED Off in Sleep Mode

ON I____I 2

Keypad Status Shows 

Stay Arm

Keypad Status Shows Stay/

Away Arm

OFF

 

I____I 3

5th Terminal is Keypad 

PGM Output

5th Terminal is Keypad Zone 

Input

OFF I____I 4

For Future Use

For Future Use

OFF I____I 5

For Future Use

For Future Use

OFF I____I 6

For Future Use

For Future Use

OFF I____I 7

Temperature Display 

Enabled

Temperature Display Disabled

OFF

 

I____I 8

Low Temperature 

Warning Enabled 

Low Temperature Warning 

Disabled 

NOTE:   Programming  options  indicated  in 

GREY

 are required for systems compliant

with EN50131-1 and EN50131-3 standards. Section [023]: 1=OFF

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____|

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____|

[041] Indoor Temperature Zone Assignment

Default

000

I_____I_____I_____I

(Valid entries are 000-128)

[042] Outdoor Temperature Zone Assignment

Default: 000 I_____I_____I_____I (Valid entries are 000-128)

The keypad can be programmed to make up to four different chime sounds for 

individual zones. e.g. for Zone 1 enter Section [101], for Zone 2 enter Section 

[102].

Default

Opt.

ON I____I

1

6 beeps

OFF I____I

2

‘Bing-Bing’ tone 

OFF I____I

3

‘Ding-Dong’ tone 

OFF I____I

4

Alarm tone (4 second 

duration)

OFF I____I

5

Zone name

OFF I____I

6-8

For future use

Summary of Contents for HS2LCDWF v1.0

Page 1: ...ual with which this equipment is intended to be used Operating Instructions shall be made available to the user NOTE This Installation Sheet applies to the following models HS2LCDWF HS2LCDWFP and HS2LCDWFPV NOTE Do not dispose of the waste battery as unsorted municipal waste Consult your local rules and or laws regarding recycling of this battery it will help protect the environ ment HS2LCDWF v1 0...

Page 2: ... directed on the back of the keypad Ensure the correct polarity is observed 3 Replace the keypad on the mounting plate desk stand Installation Instructions Temperature range 10 C to 55 C 14 F to 131 F UL ULC 0 C to 49 C 32 F to 120 F Humidity MAX 93 R H non condensing Plastic enclosure protection degree IP30 IK04 Power adaptor output voltage 9 0VDC 1 25A Mod els US Latin America xx Canada xx EU xx...

Page 3: ...is wired to the alarm panel and power has been applied power up a wireless keypad 2 Press any button on the keypad to enroll it on the HSM2HOST The HSM2HOST is then automatically enrolled on the alarm panel Enrolling Keypad 1 Enter 8 Installer Code and then section 804 000 2 When prompted either activate the device to enroll immediately or enter a device serial num ber Do the latter to pre enroll ...

Page 4: ...and select the label to change e g 8 Installer Code 000 001 to program the label for zone 01 2 Press to open the Select Options menu 3 Press again to select the Words option 4 Enter the 3 digit number corresponding to a word see Words table below or use the scroll keys to view words in the library 5 Press to select the word 6 To add another word repeat the above procedure from step 2 7 To add a sp...

Page 5: ...lost or no longer needed 1 Enter 5 and an access code with the supervisor attribute enabled 2 The keypad will display the user number and include the letter T if a prox tag is programmed 3 Scroll to Press for Prox Tag and press the key 4 The keypad will read Press To Delete Tag 5 After pressing the message Tag Deleted Successfully appears NOTE User codes can only be deleted individually NOTE User ...

Page 6: ...ommand Output 4 07 System Test 25 28 For Future Use 08 For Future Use 29 Bypass Group Recall 09 Night Arm 30 Quick Bypass 10 For Future Use 31 For Future Use 11 Away Arm no Entry 32 For Future Use 12 Global Stay Arm 33 Bypass Recall 13 Global Away Arm 34 For Future Use 14 Global Dis arming 35 For Future Use 15 For Future Use 36 Reactivate Stay Away and Night Zones Default Zone or PGM Number 00 I__...

Page 7: ...Hardware and Digital Security Controls a division of Tyco Safety Products Canada Ltd DSC the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the DSC software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy...

Page 8: ...RANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CH...

Page 9: ... X Armed Chime Duress Garage Level Office Right System A Y Arming Closed East Gas Library OK Room Tamper B Z Attic Closet Energy Glass Light On Safe Temperature C Space Auxiliary Closing Enter Goodbye Lights Open Saver Test D Apostrophe Away Code Entry Gym Living Opening Schedule Time E Dash Baby Communicator Error Hallway Load Panic Screen To F _ Underscore Back Computer Exercise Heat Loading Par...