5.0 FEATURES FOR DGP-641 ONLY

5.1 C

ONFIDENTIAL

 M

ODE

 T

IMER

Section 006 (Default: 120 seconds)

Section 

[006]

 determines the amount of time without action

before the keypad enters Confidential Mode. For more
information on Confidential Mode, refer to “Confidential Mode” on
page15. The Confidential Mode Timer can be set from 005
seconds to 255 seconds.

5.2 PGM S

TATE

 

Section 005: Option [1] 

The keypad's on-board PGM can be set as normally open or
normally closed. When an open PGM is activated, it will close the
circuit from ground and enable any devices connected to it.
When a closed PGM is activated, it will open the circuit and
disable any devices connected to it. When the PGM Activation
Event occurs (see section 5.3), the PGM will switch to its
opposite state (i.e. open to closed or closed to open).

Option

 [1] 

OFF= PGM is Normally Open (default)

Option

 [1] 

ON = PGM is Normally Closed

The PGM can provide 50mA to any device connected to it.

Summary of Contents for Digiplex DGP-641

Page 1: ...DGP 641 LCD Keypad V1 3 DGP 641ACC Access Control LCD Keypad V1 1 Reference and Installation Manual...

Page 2: ......

Page 3: ...ming 11 3 1 ENTER MODULE PROGRAMMING MODE 11 3 2 PROGRAMMING METHODS 12 3 2 1 Feature Select Programming 12 3 2 2 Decimal Programming 12 3 3 MODULE BROADCAST 12 4 0 System Options 14 4 1 PARTITION ASS...

Page 4: ...res For DGP 641ACC Only 23 6 1 BUS VOLTMETER 23 6 2 ASSIGNING DOORS TO PARTITIONS 23 6 3 READER S OPTIONS 24 6 3 1 Reader s LED To Follow Partition s Status 24 6 3 2 Reader s Beep To Follow Partition...

Page 5: ...Door Left Open Pre Alarm 29 6 5 4 Door Left Open Pre Alarm Timer 29 6 5 5 Door Left Open Alarm Feedback 30 6 5 6 Beep Timer For Door Left Open Alarm 31 6 6 DOOR FORCED OPEN OPTIONS 31 6 6 1 Door Forc...

Page 6: ...designated doors without the need of an additional control panel The events that occur on an Access Control door can be logged in the control panel s Event Buffer but can only be viewed through an Acc...

Page 7: ...Green and yellow LEDs flash simultaneously Bus fault indication Red and yellow LEDs flash alternately Tamper Switch Yes also used to deactivate locate LCD Super Twisted Nematic display STN wide viewi...

Page 8: ...lation Manual for the maximum allowable installation distance from the control panel See Figure 4 on page 10 for connection drawings for the REX device reader locking device and door contact to the de...

Page 9: ...information on zone assignment please refer to the Digiplex Control Panel s Reference Installation Manual Please note that even with the ATZ zone doubling feature enabled the keypad supports only one...

Page 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...

Page 11: ...Digiplex LCD Keypad 9n Figure 2 Typical Access Control Installation DGP 641ACC Figure 3 Access Control Overview DGP 641ACC Only...

Page 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...

Page 13: ...ns or visit our web site at www paradox ca 3 1 ENTER MODULE PROGRAMMING MODE The keypad like all other modules in the Digiplex system is programmed through the control panel To do so you must first en...

Page 14: ...isplay thereby disabling the option Press ENTER when options are set 3 2 2 Decimal Programming Sections 006 and 007 are programmed using Decimal Programming In this method any digit from 000 to 255 ca...

Page 15: ...s data If you want to program more than one keypad with the source s data enter the serial numbers of the keypads one at a time Step 6 Once you have entered the serial numbers of the keypads you want...

Page 16: ...e assigned to partitions 1 and 4 only By default partition 1 to partition 4 are enabled 4 2 DISPLAY CODE ENTRY Section 002 Option 1 The digits of the User Access Codes can be displayed on the LCD scre...

Page 17: ...re performed on the keypad for a period of time the LCD screen will appear as shown in Figure 5 page 16 and the AC and STATUS LED will be off until either a button is pressed or an access code is ente...

Page 18: ...4 ON Confidential Mode Option 5 OFF LCD screen activated by entering an access code default Option 5 ON LCD screen activated by pressing a button Figure 5 LCD Screen 4 6 MUTING Section 003 Option 1 T...

Page 19: ...Chime feature enabled closes see Digiplex User Manual for details on Chime Zones If the user does not set the Chime Zone Time Period and this option is enabled the Chime Zones will always beep upon c...

Page 20: ...ult Option 2 ON Beep enabled Communicator Troubles Option 3 OFF Beep disabled Module and Bus Troubles default Option 3 ON Beep enabled Module and Bus Troubles Option 4 OFF Beep disabled all Zone Troub...

Page 21: ...GM STATE Section 005 Option 1 The keypad s on board PGM can be set as normally open or normally closed When an open PGM is activated it will close the circuit from ground and enable any devices connec...

Page 22: ...ending on the first digit chosen 8 After entering the second digit use Feature Select Program ming page 12 to enable disable options 1 to 8 Each option represents a specific event as detailed in the P...

Page 23: ...the keypad s on board PGM is in PGM Timed Mode the value programmed in section 007 represents how long the PGM will remain in its opposite state see section 5 2 on page 19 after being activated To pr...

Page 24: ...board PGM will ignore PGM Activation Events section 5 3 page 20 PGM Deactivation Events section 5 4 page 20 and PGM Timers section 5 6 page21 It will remain in its normal state until the PGM Override...

Page 25: ...Step 1 From Normal Mode press and hold the 0 key Step 2 Enter the INSTALLER CODE by default 000000 Step 3 Press ACC The voltage may drop during the control panel battery test 6 2 ASSIGNING DOORS TO P...

Page 26: ...When this feature is enabled the reader s red LED will flash when the partition is arming in Exit Delay in Entry Delay in Burglar Alarm or in Fire Alarm Option 6 ON LED follows the door s partition s...

Page 27: ...on 8 When the REX device detects movement it can permit passage with or without turning the door handle If this option is on the door is unlocked when the REX device detects movement and users on eith...

Page 28: ...atched during the Door Unlocked Period see section 6 4 2 on page 25 but once the door is opened it can be programmed to latch as soon as the door closes or latch immediately even if the door has not c...

Page 29: ...en 7AM and 4PM and on Saturday Sunday and Holidays between 10AM and 5PM Therefore users will not have to present their Access Control Cards during the Door Unlocked Schedule 6 4 6 Card Activates Door...

Page 30: ...ntrol door is opened after an Access Granted or a Request for Exit an Access Alarm can be generated if it not closed within a certain period of time see section 6 5 2 on page 29 Option 2 ON Door Left...

Page 31: ...reader to beep a certain time before the end of the Door Left Open Interval to alert users that the Access Control door was left open and will generate an Access Alarm if it is not closed The Pre Alar...

Page 32: ...val has expired the Door Left Open Alarm can be either audible or silent and will either beep as long as the Access Alarm is occurring or follow the Beep Timer in section 010 The sound of the Door Lef...

Page 33: ...er of seconds the Access Alarm will beep default 5 seconds 6 6 DOOR FORCED OPEN OPTIONS 6 6 1 Door Forced Open Access Alarm Section 005 Options 3 If an Access Control door is opened without an Access...

Page 34: ...Open Alarm is silent If option 7 is enabled Option 8 ON Door Forced Open Alarm follows Beep Timer section 011 Option 8 OFF will beep as long as Door Forced Open Alarm is occurring default 6 6 3 Beep T...

Page 35: ...96 respectively Section 245 Paradox Family Section 246 to 249 First Second Third Fourth Area respectively After entering the section corresponding to the desired message the message can be re programm...

Page 36: ...nd at the cursor s position DISARM Numeric Keys Alphanumeric Keys Every time the DISARM key is pressed it will toggle numeric keys to alphanumeric keys and vice versa Numeric Keys 0 to 9 represent num...

Page 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...

Page 38: ...rs Access Control A tag assigned to a User Access Code used to card identify the user to the Access Control system By presenting the tag to a reader the system can verify whether the tag is valid see...

Page 39: ...must enter the Event Record Display see Digiplex Reference Installation Manual The Access Control events however can only be viewed through an Access Control Keypad DGP 641ACC Forced Door If a protect...

Page 40: ...d to it to the control panel Request for Exit When a REX device Paradoor 460 installed above an Access Control door within a protected area detects movement it sends a signal to the control panel to p...

Page 41: ...be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited...

Page 42: ......

Page 43: ......

Page 44: ......

Reviews: