Digiplex LCD Keypad 17
n
4.7 B
EEP
ON
E
XIT
D
ELAY
Section 003: Option [2]
The keypad can beep once every second during the Exit Delay
Timer. During the final 10 seconds, it will beep more rapidly to
provide a final warning before the area is armed.
Option
[2]
OFF= Exit Delay beep disabled
Option
[2]
ON = Exit Delay beep enabled (default)
4.8 C
HIME
ON
Z
ONE
C
LOSURE
Section 003: Option [4]
During the
Chime Zone Time Period
that the user sets, the
keypad can emit an intermittent beep whenever a zone with the
Chime
feature enabled closes (see
Digiplex User Manual
for
details on
Chime Zones
). If the user does not set the
Chime
Zone Time Period
and this option is enabled, the
Chime Zones
will always beep upon closure.
Option
[4]
OFF= Chime on Zone Closure disabled (default)
Option
[4]
ON = Chime on Zone Closure enabled
4.9 B
EEP
ON
T
ROUBLE
Section 004: Options [1] to [4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a
trouble condition from the Trouble Groups occurs in the system. The
intermittent beep will remain activated until the user enters the
Trouble Display
or if the trouble is resolved. For a list of the troubles,
Summary of Contents for Digiplex DGP-641
Page 2: ......
Page 10: ...8 Installer s Guide Figure 1 Connecting the Keypad and Keypad Zone...
Page 12: ...10 Installer s Guide Figure 4 Access Control Connections DGP 641ACC Only...
Page 37: ...Digiplex LCD Keypad 35n Table 2 Special Characters Catalog...
Page 42: ......
Page 43: ......
Page 44: ......