background image

For How-to videos, visit the LiftMaster Training Academy
at LiftMasterTraining.com

Installation
and Set Up Manual

KPR2000

Waterproof 
Keypad/Proximity Reader

1 2 3
4 5 6
7 8 9

*

0

#

Para Manual en Español ir a:
http://www.LiftMaster.com/CatalogResourcesV3/en-us/shared/fi les/
tucmanuals/0137261SP.pdf

Summary of Contents for KPR2000

Page 1: ...ing Academy at LiftMasterTraining com Installation and Set Up Manual KPR2000 Waterproof Keypad Proximity Reader 1 2 3 4 5 6 7 8 9 0 Para Manual en Espa ol ir a http www LiftMaster com CatalogResources...

Page 2: ...Proximity Card Reader HID 26 bit and 30 bit Sentex Radio Technology 125 KHz Industry Standard Proximity Card Read Range 1 inch 2 5 inches Wiring Connections Relay Output REX DOTL Alarm Wiegand in out...

Page 3: ...imity Key The LiftMaster KPR2000 is a single entry multi function Access Controller with integrated keypad and card reader It is designed and manufactured to perform in a wide range of indoor outdoor...

Page 4: ...stallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications...

Page 5: ...ptional Face Plate 1 81 4 6 cm 29 74 cm 3 7 6 cm 2 4 6 1 cm 4 10 2 cm 4 10 2 cm INTRODUCTION INSTALLATION WIRING SET UP INSTALL THE KPR2000 The KPR2000 fits a standard single outlet box or a 2 4 6 1 c...

Page 6: ...a valid Wiegand Card to the KPR2000 and then enter their PIN code followed by the key in order to be granted access PASS THROUGH OPERATION KPR2000 WITH TELEPHONE ENTRY SYSTEM The KPR2000 passes all k...

Page 7: ...Pass through Input Stand Alone Data 0 White Data 1 Wiegand Output Pass through Input Stand Alone Data 1 Pink Ground Ground reference for Wiegand Output Input ADVANCED INPUT AND OUTPUT FEATURES Yellow...

Page 8: ...ly and shown for DC applications Black DC Red DC Pink White Green The example below uses the EL25 EL2000SS Wiegand Module WOMDKT KPR2000 can be connected to other access systems with the same Wiegand...

Page 9: ...nd shown for DC applications Yellow Red Black Orange Purple Normally Closed Gray 1 Amp Maximum Pink Yellow Brown Door Contact Request to Exit For DC Power Install a 1N4007 or equivalent diode For AC P...

Page 10: ...en Blue Purple Gray Pink 1 Amp Maximum Black Pink Red For DC Power Install a 1N4007 or equivalent diode For AC Power S10K30MOV Metal Oxide Varistor not provided KPR2000 Stand Alone Master Unit KPR2000...

Page 11: ...ACCESS CONFIGURATION NOTE See page 6 for description of each operation mode There are 3 types of access configurations for the KPR2000 Card or PIN Default The User must present a valid Wiegand Card to...

Page 12: ...ATION The relay configuration sets the behavior of the output relay on activation SET WIEGAND INPUT OUTPUT OPTIONS The KPR2000 offers input and output for industry standard Wiegand devices refer to Sp...

Page 13: ...or 10 minutes 7 2 3 Exit Program Mode Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 DOTL Door Forced Alarm OFF OR 2 DOTL Door Forced Alarm ON 6 0 6 1 DOTL Alarm sounds for...

Page 14: ...on 1 Enter Program Mode Master Code 2 Set Facility Code 8 0 Ignores facility code Factory default 8 Facility Code 1 255 3 Exit Program Mode SET 26 BIT FORMAT FACILITY CODE SET AUDIBLE AND VISUAL RESPO...

Page 15: ...ical Modifications to user data require either the card or the User ID be available Proximity Card Any 125 KHz industry standard 26 bit Wiegand Proximity Card or 30 bit Sentex Proximity Card Keypad PI...

Page 16: ...p to 2000 cards to the KPR2000 in a single step Takes 2 minutes to program 1 Read Card Repeat Step 2 for additional user cards See Notes 1 and 2 1 User ID Read Card See Notes 1 and 2 5 User ID The fir...

Page 17: ...dditional memory DELETE USER CARD S Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Delete Card By User ID OR 2 Delete Card By Card OR 2 Delete Card By Card Number 2 User ID...

Page 18: ...e user must change the PIN using card to activate the PIN for this user If the PIN is assigned first a second user ID must be used to assign the card NOTE 2 When adding or deleting multiple users sequ...

Page 19: ...Auto User ID enrollment and is only available in Card Only configuration Programming Step Keystroke Combination Add a User Card 1 Read Manager Add Card 2 Read User Card Repeat Step 2 for additional us...

Page 20: ...reset the door open too long DOTL warning Read valid card OR Master Code ANTI TAMPER ALARM The KPR2000 uses an optical sensor as the input for its internal alarm If the case is opened while the KPR200...

Page 21: ...2 Press and hold the button while power is restored to the KPR2000 3 Release the button and wait until the amber LED shines 4 Present any 26 bit proximity card or the Manager Add Card provided to the...

Page 22: ...Step Successfully ON Single Flash Single Beep Entered Continuous Program Step Successfully Single Flash ON Single Beep Entered Continuous Program Step Incorrectly ON 3 Beeps Exited from Program Mode F...

Page 23: ...n LiftMaster LiftMasterTraining com Manuel d installation et de configuration KPR2000 Clavier Imperm able Lecteur de Proximit 1 2 3 4 5 6 7 8 9 0 Para Manual en Espa ol ir a http www LiftMaster com Ca...

Page 24: ...r bit ASCII Lecteur de proximit Formats de sorties HID Wiegand 26 et 30 bits Sentex Technologie radio Lecteur de proximit de 125 KHz conforme aux normes de l industrie Port e de lecture de 2 5 cm 6 35...

Page 25: ...KPR2000 supporte jusqu 2000 usag s qui utilisent des configurations multiples d acc s carte seule carte ou NIP ou carte et NIP Le liseur de cartes int gr 125 KHz accepte les formats des cartes de prox...

Page 26: ...radio et s il n est pas install et utilis conform ment aux instructions causer des interf rences nuisibles aux communications radio Cependant il n existe aucune garantie que des interf rences ne se pr...

Page 27: ...RATION INSTALLATION DU KPR2000 Convient une bo te de sortie standard unique ou un socle carr 6 1 cm 2 4 po monter Plaque de garniture 142A0271 facultatif T ti re 4 6 cm 1 81 po 74 cm 0 29 po 7 6 cm 3...

Page 28: ...abord ins rer une carte Wiegand valide dans le KPR2000 et entrer son NIP suivi de la touche Carr pour se voir autoriser l acc s FONCTIONNEMENT PASSAGE CONTR L KPR2000 AVEC SYST ME D ACC S PAR T L PHO...

Page 29: ...passage contr l Entr e autonome Donn es 0 Blanc Donn es 1 Sortie Wiegand passage contr l Entr e autonome Donn es 1 Rose Mise la terre R f rence de masse pour sortie entr e Wiegand CARACT RISTIQUES AV...

Page 30: ...pour la mise en r seau de 2 KPR2000 Alimentation c a ou c c et montr es pour les applications c c L exemple ci dessous utilise le module Wiegand EL25 EL2000SS WOMDKT Le KPR2000 peut tre connect d autr...

Page 31: ...u Jaune Marron Pour une alimentation CC Installation d une diode IN4007 ou l quivalent Pour une alimentation CA S10K30MOV varistance oxyde m tallique no forni CA ou CC Contact de porte Alarme externe...

Page 32: ...rt Bleu Pourpre Gris Rose ou 1 A maximum Noir Rose Rouge Vert donn e 0 Maximum de 152 4 m 500 pi Blanc donn e 1 Maximum de 152 4 m 500 pi Rose doit se connecter la terre Maximum de 152 4 m 500 pi KPR2...

Page 33: ...e ma tre tape de la programmation Configuration du clavier 1 Entr e dans le mode utilisateur Code ma tre 2 Changement du code ma tre 0 Nouveau code Nouveau code 3 Sortie du mode utilisateure CONFIGURA...

Page 34: ...onfigure le fonctionnement de la sortie de relais d s l activation CONFIGURATION DES OPTIONS D ENTR E DE SORTIE WIEGAND Le KPR2000 offre des options d entr e et de sortie pour les appareils Wiegand co...

Page 35: ...LACER LA PORTE OUVERTE TROP LONGTEMPS DOTL OU FORC E ALARME Ce param tre permet la fois DOTL portes et alarmes forc et n cessite une entr e de capteur externe Le forc calendrier de sortie d alarme de...

Page 36: ...lation 8 0 Ignore code site d faut d usine 8 Code de l installation 1 255 3 Sortie du mode utilisateur SET 26 BIT CODE FORMAT DES INSTALLATIONS CONFIGURATION D UNE R PONSE AUDIBLE OU VISUELLE Le r gla...

Page 37: ...t cruciale Les modifications aux donn es d utilisateurs exigent soit une carte ou soit un num ro d identification de l utilisateur disponible Lecteur de proximit Tout lecteur de proximit de 125 KHz Wi...

Page 38: ...onnecter jusqu 2000 lecteurs au KPR2000 en une seule tape Cette programmation s ex cute en 2 minutes 1 Lire la carte R p tez l tape 2 pour des cartes d utilisateurs suppl mentaires Voir Remarques 1 et...

Page 39: ...ion Configuration du clavier 1 Entr e dans le mode utilisateur Code ma tre 2 Suppression d une carte au moyen du num ro d identification de l utilisateur OU 2 Suppression d une carte au moyen d une ca...

Page 40: ...sateurs de fa on s quentielle la commande de programme 1 ou 2 respectivement est inscrit uniquement au d but de la proc dure Pour les utilisateurs suppl mentaires entrez l ID utilisateur et mot dans l...

Page 41: ...ntification de l utilisateur et n est possible qu avec la configuration Carte seule tape de la programmation Configuration du clavier Ajout d une carte d utilisateur 1 Lire la carte d extension de l a...

Page 42: ...ertissement d une porte rest e ouverte trop longtemps DOTL Lire une carte valide OU Code ma tre INTRODUCTION INSTALLATION CONFIGURATION C BLAGE ALARME ANTI PIRATAGE Le KPR2000 utilise un capteur optiq...

Page 43: ...ant que le KPR2000 est remis sous tension 3 Rel cher le bouton et attendre jusqu ce que le voyant DEL jaune s allume 4 Pr sentez au KPR2000 n importe quel lecteur de proximit de 26 bits ou une carte d...

Page 44: ...tape de programmation unique effectu e avec succ s Sous tension Clignotant unique Bip unique et court tape de programmation continue effectu e avec succ s Clignotant unique Sous tension Bip unique et...

Reviews: