BA_PH_BSB-400-900_EN_44-21.docx
44
Troubleshooting - Continuation
Fault
Possible Cause
Remedy
Saw blade breaks
Bad weld
→
Replace saw blade
Too sharp edges at the tooth base
→
Use a saw blade that is
suitable for the intended use
Saw blade guide badly adjusted, the
back roller presses against the saw blade
→
Readjust saw blade guide
according to section
Manual feed rate too high
→
Select feed rate according
to the material
Saw blade blunt or badly set
→
Replace saw blade
Saw blade torn or teeth burnt
due to incorrect grinding
→
Regrind or replace
Resin residues or similar on the saw blade
→
Clean the saw blade
and the wheel bandages
Saw blade badly ground or
teeth not adapted to the cut
→
Replace saw blade
Red lamp
10
„
Fault
“
on
the control panel lights
up
Fault on the frequency inverter
→
Note the error message
and contact customer service.
Caution: Frequency inverter
remains energised for up to 15
minutes after the main switch
is turned off!
Note:
In case of problems with the saw blade guides follow the instructions in section
10
This fault only occurs on models with variable blade speed control.