9
P10
Pass word
range: 0-9
Please contact with the sales agent if required.
Default
:
123456
P11
Network setting
0
:
Forbid
--to set the Menu P11 be as 0.
1
:
Allow
--to set the Menu P11 be as 1.
Default
:
1
P12
Arc start current
correction
-50-+50A
Menu P12 sets the value to be the upper and lower range
adjustment of the arc start current under the state of the set
arc start current level. The range is -50A to +50A
Remarks: the correction will no work once the arc start
current reached to the lower limitation.
Default
:
0
P13
Arc start time
correction
-30-+30ms
--
Menu P12 sets the value tobe
Arc start time correction,
the correction range is -30-+30ms
Default
:
0
P14
Special
Frequency
setting
0
:
N/A
--to set the Menu P14 be as 0.
1
:
Available
--to set the Menu P14 be as 1. The output frequency is
2KHZ. At this time, enter the Pulse frequency setting states,
the right side display meter will show SPF, the PULSE FREQ
& PULSE WIDTH are not adjustable.
Default
:
0
P18
Low non-load
output
0
:
non-load output
--to set the Menu P18 be as 0. There will be non-load output
under the STICK mode.
1
:
safety low voltage output
--to set the Menu P18 be as 1. There will be safety low
voltage output under the STICK mode.
Default
:
0
P22
Up & down
slope(%) of spot
welding
range: 0-50
--Menu P22 sets the value to be the Up & down slope(%).
This value is adjustable. When the value is 0, the output is
square wave; When the value is 50, the output is triangular
wave.
Default
:
5
P23
Loop resistance
test
0
:
normal state
--to set the Menu P23 be as 0.
1
:
Loop resistance test
--to set the Menu P23 be as 1, set the MODE as WELD,
ensure the tip closely contacts with the base metal, press the
torch switch, the display meter will show the resistance value
(unit: Ω). The right side display meter shows the integer, the
left side display meter shows the digits. This function is
normally selected when the extension cable was used. After
the test, power on the machine for use.
Default
:
0
Factory Settings are as follows:
Power switch OFF/DC TIG/CRATER OFF/WELD/HF/GAS CHECK OFF
Summary of Contents for YC-400TX4
Page 2: ......
Page 17: ...11 5 2TIG PLUSE TIG WATER ...
Page 35: ...29 12 Parts list 12 1 Parts list for YC 400TX4 Front view 1 3 4 5 2 6 ...
Page 36: ...30 Right View Left view 7 12 11 13 19 20 10 8 9 21 14 15 18 16 17 23 22 26 24 27 25 ...
Page 38: ...32 13 Outline drawing ...
Page 39: ...33 14 Circuit diagram ...