8
“F.Adj” Manu Functions Table
Menu
Contents
Instructions
Factory
Settings
P01
Cooling Mode
0
:
air cooling
if the Menu P01 to be set as 0, it is air cooling mode.
1
:
controlled water cooling
if the Menu to be set as 1, it is water cooling mode, the water
cooling tank is required and the cooling is controlled by the
systems.
2
:
non-controlled water cooling
-if the Menu to be set as 2, it is water cooling mode, the water
pump and cooling fan will run right after the power on, no
need the system control.
Remarks: 1) the initial setting is controlled water cooling, if
the air cooling was required, please set the P01 to be as 0; 2)
5s after the power on, set the P01 to be as 0 in order to
switch the cooling mode from non-controlled water cooling to
air cooling, or complete the P01 set up before removing the
water cooling tank, otherwise it may cause Err11 alarming.
Default: 1
P02
Arc Start Level
0
:
too weak
-to set the Menu P02 to be as 0
1
:
weak
to set the Menu P02 to be as 1
2
:
standard
to set the Menu P02 to be as 2
3
:
strong
to set the Menu P02 to be as 3
Remarks: the arc start level works for DC TIG, Pulse TIG &
STICK welding modes.
Default: 2
P03
Voltage display
0
:
OFF
to set the Menu P03 to be as 0.
1
:
ON
to set the Menu P03 to be as 1.
Default: 0
P04
Arc breaking
(when crater is
REPEAT)
0
:
PULL to break
to set the Menu P04 to be as 0.
1
:
double-press the torch switch to break
to set the Menu P04 to be as 1.
Default: 0
P05
Tungsten
electrode short
circuit check
0
:
OFF
;
to set the Menu P05 to be as 0.
1
:
ON
to set the Menu P04 to be as 1.
Default: 0
P06
Display the
duration time
0.0-10.0s
;
The Menu P06 setting value is the time of continuous flashing
of current and voltage at the end of welding.
Default:
5.0s
P07
Maximum output
limitation
;
range: 50-400A
The Menu P07 setting value is the welding output limitation.
The pre-set current will not exceed this value after the
setting.
Default
:
400A
P08
The setting
mode of the
post-flow
0
:
manual
to set the Menu P08 to be as 0.. the default value of the post-
flow time is 5s. It can be adjusted manually.
1
:
auto
to set the Menu P08 to be as 1,
Crater OFF: the post-flow time will be changed when the
welding current changes.
Crater ON: the post-flow time will be changed when the
crater arc current changes.
Default
:
1
P09
address
range: 0-255
The Menu P09 setting value is the IP address for the
Default
:
1
Summary of Contents for YC-400TX4
Page 2: ......
Page 17: ...11 5 2TIG PLUSE TIG WATER ...
Page 35: ...29 12 Parts list 12 1 Parts list for YC 400TX4 Front view 1 3 4 5 2 6 ...
Page 36: ...30 Right View Left view 7 12 11 13 19 20 10 8 9 21 14 15 18 16 17 23 22 26 24 27 25 ...
Page 38: ...32 13 Outline drawing ...
Page 39: ...33 14 Circuit diagram ...