25
10 Troubleshooting
Touching the current-carrying parts may cause a fatal electric shock
orburn injury.
To prevent a physical accident, such as an electric shock, burn injury, etc., make sure to
observe the followings.
● To ensure safety, troubleshooting work shall be done by qualifiedpersonnel.
● Make sure to turn off the power and other switches of all devices
*
for safety reasons
before taking any actions for correcting anerror.
*
: Includes this product, the distribution box and other related devices (jigs, robots, etc.).
● In case of performing the inside inspection, make sure to work at least five minutes after
the power is turned off (for capacitordischarge).
10.1 Error indication
■
When a self-diagnosable erroroccurs,“Err”(forerror)anderrorcodecanbedisplayedonthe operationpanel.
■
See thefollowing table ford etailsoftheerrorcodes.
(Note)About“Group”inthetable
● Group“A”:ItisnotnecessarytoturnpowerswitchOFF.(Thedisplaysareautomaticallyturned off when the cause isremoved.)
● Group“B”: ItisnecessarytoturnpowerswitchOFFandbackONagain.(ThedisplayscanNOT
beautomaticallyturnedoffuntilthepowerswitchisturnedOFFevenwhenthecauseisremoved.)
Err
S/N
Error type
Group
Probable causes and remedy
Err
001 emergency stop
B
The connection of external equipment emergency stop on the output terminal
block.
TurnpowerswitchOFF,refertothelistbelowand
removethecauseandthenturnpowerswitchONagain.
malfunctionfromexternalequipmentemergencystop.
malfunctionfromswitchpowersourcePCBinthisequipment.
Err
002
secondary over-
current
error
A
Over-current due to short-circuit in the secondary circuit or so on.
TurnweldinggunswitchOFFandremovethecauseofthe over current.
Err
003
temperature rise
error
A
Rise in temperature inside this welding power source. Please do NOT turn OFF
the machine before the temperature in the Product decreases.
<Remedy>
Keeptheinputpowerinnoloadstateandwaitfora while. The error code indication
automatically turned off when the power source is cooleddown.
Check and remove causes of over-heat.
Over dutycycle,
Airflowblockingatventilationandcoolingfan windows
Iftheproblemcannotbesolvedbytheabove-mentioned
activities, please clean the cooling fan.
Summary of Contents for YC-400TX4
Page 2: ......
Page 17: ...11 5 2TIG PLUSE TIG WATER ...
Page 35: ...29 12 Parts list 12 1 Parts list for YC 400TX4 Front view 1 3 4 5 2 6 ...
Page 36: ...30 Right View Left view 7 12 11 13 19 20 10 8 9 21 14 15 18 16 17 23 22 26 24 27 25 ...
Page 38: ...32 13 Outline drawing ...
Page 39: ...33 14 Circuit diagram ...