![background image](http://html.mh-extra.com/html/panasonic/wv-cpr460/wv-cpr460_operating-instructions-manual_277843036.webp)
-36-
Because the alarm signal is multiplexed on the
video signal, it may be mistakenly interpreted by
other video equipment as a time code signal.
Therefore, when the camera is not used in a
Panasonic Intelligent CCTV System select OFF to
prevent the above from occurring.
• To confirm the changed parameter of Alarm Data
Setting on the RS485 Setup menu for DISPLAY
MODE, move the cursor to RET to return to the
previous menu and move the cursor to END to
close the menu once.
9. Lens Drive Signal Selection (LENS DRIVE)
This item is used to select the type of auto iris lens
drive signal to be supplied to the lens from the auto iris
lens connector.
1. Move the cursor to the LENS DRIVE parameter.
2. Select DC if you are using the auto iris lens that
requires a DC drive signal.
Select VIDEO if you are using the auto iris lens that
requires a video drive signal.
10. Special Menu
This menu lets you adjust and setup the video signal of
the camera to meet your requirements.
Move the cursor to RET on the bottom line of the CAM
SET UP menu and press
L
or
M
simultaneously
(holding down
L
and press
M
) for 2 seconds or
more. The SPECIAL menu appears on the monitor as
shown at right.
** CAM SET UP **
CAMERA ID OFF
ALC/ELC ALC
SHUTTER ---
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW
MOTION DET OFF
LENS DRIVE DC
RET
↵
↵
↵
** SPECIAL **
UP SIDE DOWN OFF
CHROMA GAIN ....I....
AP GAIN ....I....
PEDESTAL .I.......
- +
CAMERA RESET PUSH SW
RET END
10-1. Camera Picture Upside Down Positioning
(UP SIDE DOWN)
1. Move the cursor to the UP SIDE DOWN parameter.
2. Select ON when you want to turn the picture
upside down.