Install the recorder into an EIA standard compliant rack.
Note:
•
Installation in a rack re
q
uires four M5 x 12 scre
w
s.
1
Remove the 5 rubber feet from the underside of the
recorder.
Use a scre
w
driver to remove the scre
w
s holding the ru
bb
er
feet.
2
Attach the handle for rack mountin
g
bracket to the rack
mountin
g
brackets.
Use the four handle fixing scre
w
s for rack mounting
b
racket
and
w
ashers to secure them.
3
Attach the rack mountin
g
bracket to both sides of the
recorder.
Secure them using the six rack mounting
b
racket fixing
scre
w
s.
4
Install the recorder in the rack.
Secure using the rack mounting scre
w
s.
Rack Mountin
g
EIA standard compliant
product
(locally procured)
: an EIA-standard 19"rack, depth
550 mm or more
Remo
v
e r
u
bber feet
Handle for rack mo
u
nting bracket
Rack mo
u
nting bracket
Handle fixing screws for
rack mo
u
nting bracket
Washer
Washer
Rack mo
u
nting brackets (pro
v
ided)
Handle for rack
mo
u
nting bracket
Handle for rack
mo
u
nting bracket
Rack mo
u
nting bracket fixing screws (pro
v
ided)
Important:
•
Ensure that the temperature inside the rack does not exceed
45 ºC {113 ºF}.
•
During installation,
w
e recommend installing a fan to keep the
temperature in the rack
b
elo
w
30 ºC {
8
6 ºF}.
•
W
hen installing the recorder in the rack, leave a space of
1 unit (44 mm {1.73"}) a
b
ove and
b
elo
w
each unit.
•
Leave space
b
et
w
een racks and ensure proper ventilation
around the racks.
Rack mo
u
nting screws (M5 x 12, locally proc
u
red)