58
6 1 1 A L A R M L O G ( T R A N S ) 1 / 3
N O . D A T E T I M E A L M #
2 3 1 5 / 0 7 / 9 9 2 3 : 3 0 : 3 5 1
2 2 1 1 / 0 7 / 9 9 1 2 : 3 4 : 0 1 2
2 1 1 1 / 0 7 / 9 9 0 9 : 3 4 : 0 1 4
2 0 1 0 / 0 7 / 9 9 1 8 : 3 4 : 0 1 5
1 9 0 9 / 0 7 / 9 9 1 8 : 3 4 : 0 1 7
1 8 0 9 / 0 7 / 9 9 2 2 : 3 4 : 0 1 4
1 7 0 4 / 0 7 / 9 9 1 4 : 3 0 : 0 1 4
1 6 2 8 / 0 6 / 9 9 1 4 : 3 0 : 0 1 3
1 5 2 7 / 0 6 / 9 9 1 0 : 3 4 : 0 1 1
1 4 0 1 / 0 5 / 9 9 2 3 : 5 9 : 0 1 1
↑
: N E X T A L A R M
↓
: P R V A L A R M E S C : P R V
●
Alarm Log [610]
Up to 100 items on the alarm log can be verified. If the number exceeds 100, then the earlier part of the log will be recorded
over. The alarm log recorded at a remote site can be downloaded to the control site for verification.
Date when alarms occurred
Time when alarms occurred
Sensor IN No.
Page/Total No. of pages
6 1 0 A L A R M L O G
6 1 1 A L A R M L O G ( T R A N S )
↓
6 1 2 A L A R M L O G ( R E C E I V E R )
↓
↑ ↓
: M O V E E N T : S E L E C T E S C : P R V
1
Move the cursor to the desired item for
display.
• 611 ALARM LOG (Transmitter)
The dates and times of sensor operation at the remote
site and the alarm numbers are displayed. When this
item is selected at the control site during communica-
tion, the alarm log recorded of the remote site can be
downloaded for display.
• 612 ALARM LOG (Receiver)
This item can be selected only at the control site
(Receiver). The alarm dialing sites, dates, times, etc.
can be verified.
2
Press the ENTER button.
The alarm log is displayed when the
ENTER
button is
pressed.
●
Alarm Log (Transmitter)
6 1 0 A L A R M L O G
6 1 1 A L A R M L O G ( T R A N S )
↓
6 1 2 A L A R M L O G ( R E C E I V E R )
↓
↑ ↓
: M O V E E N T : S E L E C T E S C : P R V
a
a
Select the item 611 during communication and press the
ENTER
button.
Log is shown after transfer
■
N O W D A T A T R A N S F E R R I N G
P L E A S E W A I T
E S C : Q U I T
• After downloading is over, the latest 10 items are dis-
played. To display the alarm log, press the
▼
button.
• The latest 100 items can be displayed upon starting
transfer. The alarm inputs to the remote site after
starting transfer are not displayed. (The log is record-
ed at the remote site.)
• When this menu is selected at the remote site, the
alarm log recorded at the local site can be verified.
Notes
Can be verified after terminating communication.
Alarm logs are cleared when the
DELETE
button
is pressed during alarm log display.
Note