51
4 7 0 S E Q . S C A N S E T U P
S E Q . S C A N : O N O F F
D W E L L T I M E : . . S ( 0 2 S - 3 0 S )
R E S T A R T T I M E : . . 0 S ( 0 1 0 S - 3 0 0 S )
↑ ↓ ← →
: M O V E E S C : P R V
●
Alarm Memory Method Setup [480]
The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you set the alarm storage method in the codec at the remote site when an alarm is received from an associated
alarm sensor.
4 8 0 V I D E O M E M O R Y
A L A R M M E M O R Y : P R E / P O S T P R E O N L Y
← → :
S E L E C T E S C : P R V
1
Move the cursor to the SEQ. SCAN parameter.
Then select either ON or OFF by pressing the
Direction buttons.
ON:
Enables sequential scan.
OFF:
Disables sequential scan.
2
Move the cursor to the DWELL TIME
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the length of time that is monitored at
each view point.
It can be specified from 2 to 30 seconds in 1-second incre-
ments.
3
Move the cursor to the RESTART TIME
parameter. Then enter a specific time by
pressing the numeric buttons.
This item lets you set the restart time to return to sequential
scan when a view point is manually controlled during a
scan.
It can be specified from 10 to 300 seconds in 10-second
increments.
* Pre and Post frame
A pre-frame is a frame stored in the memory during stand-
by state or prior to input of the alarm.
A post-frame is a frame stored in memory after an alarm
input.
1
Move the cursor to the ALARM MEMORY
parameter. Then select either mode by
pressing the Direction buttons.
PRE/POST:
Enables storage of pre and post frames (video
and audio).
About 20-seconds of pre-frames and 20-seconds of
post-frames can be stored.
PRE ONLY:
Enables storage of about 40-seconds of pre
frames only (video and audio).
Storage pre and post frames
When PRE/POST is set for this item, no alarm dialing
takes place till the alarm storage is over after the alarm
input.
●
Sequential Scan Setup [470]
The following procedures are only available when the AV Codec is set to TRANSMITTER in the [100 MODE] menu.
This menu lets you enable or disable sequential monitoring of view points (1 to 8) at the remote site. This function is available
in a standby state and during communication.
Transmitter
Storage Time
The storage time differs between 30-seconds and 40-
seconds depending on the movement or intricacy of
the objects.
Similarly it may be less than 20-seconds for pre and
post frames.