Product Outline
PACD011001C2
410
General Information UM Combination “MA1R Series” Using R-407C
Other versatile
functions are
provided
„
Individual control of up to 20 indoor units with one 20HP class outdoor unit
„
For Urban Multi Combination
„
Others
„
High efficiency with power factor of 90% or higher
„
Cooling operation with outdoor air temperature as low as –5°C
„
Heating operation with outdoor air temperature as low as –15°C
„
Simple Branch piping system
„
Super wiring system
„
Automatic address setting function
„
Built-in wiring error check function
„
Equipped with sequential start function
„
Nighttime low-noise mode for reduced operating sound
„
Long refrigerant piping : equivalent
length of 125, actual length of 100 m
and height difference of 50 m.
„
Connection of indoor unit of varying
capacities and types totaling 130%
(max.) of outdoor unit by capacity.
Outdoor unit name
No. of indoor units connectable
PA-16~20MA
20 units
PA-24~30MA
32 units
Height difference
between indoor units
15m
100m
Actual height difference
between indoor unit and
outdoor unit
50 m
40 m
from first Branch
to last indoor unit.
(In case of the outdoor
unit located upper position
than the indoor unit)
(V0804)
(V0805)
Summary of Contents for Urban Multi MX1R Series
Page 13: ...PACD011001C2 xii Table of Contents ...
Page 23: ...PACD011001C2 2 Urban Multi MX1 ME1 Series Using R 22 ...
Page 125: ...Test Operation PACD011001C2 104 Test Operation Urban Multi MX1 ME1 Series Using R 22 ...
Page 155: ...Test Operation PACD011001C2 134 Test Operation Urban Multi MX1 ME1 Series Using R 22 ...
Page 239: ...PACD011001C2 218 Urban Multi MX1R ME1R Series Using R 407C ...
Page 245: ...Outline PACD011001C2 224 General Information Urban Multi MX1R ME1R Series Using R 407C ...
Page 293: ...Function PACD011001C2 272 Function Urban Multi MX1R ME1R Series Using R 407C ...
Page 343: ...Test Operation PACD011001C2 322 Test Operation Urban Multi MX1R ME1R Series Using R 407C ...
Page 427: ...PACD011001C2 406 UM Combination MA1R Series Using R 407C ...
Page 433: ...Product Outline PACD011001C2 412 General Information UM Combination MA1R Series Using R 407C ...
Page 501: ...Test Operation PACD011001C2 480 Test Operation UM Combination MA1R Series Using R 407C ...
Page 586: ...PACD011001C2 Wiring Diagrams Outdoor Unit Appendix 565 CZ 100 160HR1HE ...
Page 590: ...PACD011001C2 Wiring Diagrams Outdoor Unit Appendix 569 CZ 100 160HR1HP ...
Page 592: ...PACD011001C2 Wiring Diagrams Outdoor Unit Appendix 571 PA 24 26 28 30MA1XPK ...
Page 594: ...PACD011001C2 Wiring Diagrams Indoor Unit Appendix 573 CS 40 50 80 125LMHPP ...
Page 596: ...PACD011001C2 Wiring Diagrams Indoor Unit Appendix 575 2 3 Corner Type CS 25 32 40 63DM1HPK ...
Page 598: ...PACD011001C2 Wiring Diagrams Indoor Unit Appendix 577 CS 80 100 125FMHPP ...
Page 600: ...PACD011001C2 Wiring Diagrams Indoor Unit Appendix 579 CS 200 250EMHPK ...
Page 601: ...Wiring Diagrams Indoor Unit PACD011001C2 580 Appendix 2 6 Ceiling Type CS 32 63 100TMJPL ...
Page 604: ...PACD011001C2 Wiring Diagrams Indoor Unit Appendix 583 2 9 Small Duct Type CS 20 25NM1HPP ...