Mini VRF SYSTEM
Trouble Diagnosis
3
3-3
1. Contents of Remote Controller Switch Alarm Display
ON:
Blinking:
OFF:
Possible cause of malfunction
Activation of
protective
device
Thermistor
fault
EEPROM on indoor unit PCB failure
Protective
device for
compressor is
activated
Protective device for
compressor is activated.
Protective device in outdoor
unit is activated.
Indoor thermistor is either
open or damaged.
Outdoor thermistor is either
open or damaged.
High-pressure switch
Incorrect discharge temperature (Comp.)
Power supply circuit failure, missing-phase detection
There is a trouble with the outdoor unit when the liquid valve
and the gas valve are closed.
Outdoor unit fan motor is unusual.
Compressor running failure resulting from missing phase in the
compressor wiring, etc. (Start failure not caused by IPM or no gas.)
Missing-phase/reverse-phase in the compressor wiring,
Compressor start-up failure (Overcurrent at time of INV
compressor starts up, etc.)
IPM trip (IPM current or temperature)
Indoor coil temp. sensor (E1)
Indoor coil temp. sensor (E3)
Indoor suction air (room) temp. sensor (TA)
Indoor discharge air temp. sensor (BL)
Comp. discharge gas temp. sensor (TD)
Outdoor coil liquid temp. sensor (C1)
Outdoor air temp. sensor (TO)
Compressor intake port temperature sensor (TS)
High pressure sensor
EEPROM on the outdoor unit PCB has failed.
Power supply current (CT) sensor failure
(Current is not detected at time of compressor ON.)
Overcurrent of power supply current (CT) sensor
PAM failure
P13
P05
P04
P03
P16
P22
P29
H31
<<F01>>
<<F03>>
<<F10>>
<<F11>>
F04
F07
F08
F12
F16
F29
F31
H03
H02
H01
Operation
Standby
for heating
Wired
remote
control
display
Wireless
remote controller
receiver display
Timer
Timer lamp blinking
Timer lamp blinking
Operating and
timer lamp blinking
simultaneously
Operating and
timer lamp blinking
simultaneously
Operating and
heating ready
lamp blinking
altemately
Operating and
timer lamps
blinking alternately
Operating and
timer lamps
blinking alternately