6-
5
When adjusting the height, no more that 4 holes should be visible. (The white line should not show.)
Distance from
center of display
to ceiling ( in.)
Center of
display
Height adjustment
holes
1085mm (42
23/32
)
985mm (38
25/32
)
885mm (34
27/32
)
785mm (30
29/32
)
Washer pan nut
Spring washer
Fixing bolt (M8-100)
Fixing bolt
(M8-12)
Hidden
side
Ceiling unit
(upper section)
Fixing bolt (M8-12)
Fixing bolt (M8-12)
White line
(Example)
Ceiling unit
(lower section)
Attach the ceiling unit (lower section)
1) Match the height adjustment holes on the upper and lower sections
to the desired height and refasten in place with two M8 assembly
screws.
2) Insert the fixing bolt (M8-100) through the spring washer and then
insert it through the uppermost hole in the pipe. Fasten in place with
the washer pan nut (all included).
3) Tighten with two fixing bolts (M8-12, included) so that the lower
section does not move.
2
Fixing bolt (M8-100)
Spring washer
Washer pan nut (M8)
Fixing bolt (M8-12) x 2