Specifications and Dimensions
SF4C Safety light curtain
114
7.2 Common Specifications
Type
Cable type
Pigtailed type
Model No.
SF4C-H-
□
SF4C-H-
□
-J05
Sensing range
0,1 to 3m
Beam pitch
20mm
Detecting capability (Min.
object to be sensed)
Ø25mm opaque object
Effective aperture angle
(EAA)
±
2.5° or less for sensing range exceeding 3m
(required by IEC 61496-2/UL 61496-2)
Supply voltage
24V DC
+10
-15
%. Ripple P-P 10% or less
Control output
(OSSD 1, OSSD 2)
PNP open-collector transistor/NPN open-collector transistor (switching type)
•
For PNP output: Max. source current 200mA
•
For NPN output: Max. sink current 200mA
Applied voltage: same as supply voltage (for PNP output: between the control output
(OSSD 1/2) and +V, for NPN output between the control output (OSSD 1/2) and 0V).
•
Residual voltage: 2.5V or less (For PNP output: source current 200mA, for NPN
output: sink current 200mA) (when using 10m length cable)
•
Leakage current: 200µA or less, when power supply is OFF
•
Maximum load capacity: 1µF (no load to maximum output current)
•
Load wiring resistance: 3
Ω
or less
•
Operation mode: ON when all beams are received, OFF when one or more beams
are interrupted (Note 1, 2), OFF when fault occurs in the sensor or the
synchronization signal error, too.
•
Protection circuit: Incorporated
Response time
In normal operation: OFF: 7ms or less, ON: 90ms or less
Auxiliary output
(Non-safety output)
PNP open-collector transistor/NPN open-collector transistor (switching type)
•
For PNP output: Max. source current 100mA
•
For NPN output: Max. sink current 100mA
•
Applied voltage: same as supply voltage (for PNP output: between the auxiliary
output and +V, for NPN output between the auxiliary output and 0V)
•
Residual voltage: 2.5V or less (In case of selecting PNP output: source current
100mA, in case of selecting NPN output: sink current 100mA) (when using 10m
length cable)
•
Operation mode: When OSSDs are ON: OFF, When OSSDs are OFF: ON (factory
setting). This setting can be changed with the optional handy controller SFC-HC.
•
Protection circuit: Incorporated
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG