Before Using this Device
SF4C Safety light curtain
14
2.3.2 Operation
of
Large
Multi-Purpose Indicator
You have different settings available for the large multi-purpose indicator with the handy
controller SFC-HC (optional), see page 84. One mode can be selected from the following eight
mode numbers. Factory setting is mode 0.
Large multi-purpose indicator input
1/2
OSSD 1/2
Muting
function
Override
function
Mode
PNP
output:
ON
NPN
output:
OFF
PNP
output:
OFF
PNP
output:
ON
ON
OFF
Active
Inactive
0
Lights up red
Lights up green
–-
–-
–-
–-
1
Blinks red
Blinks green –-
–-
–- –-
2
Lights up red
Blinks green
–-
–-
–-
–-
3
Blinks red
Lights up green
–-
–-
–-
–-
4
Lights up red
Blinks red
–-
–-
–-
–-
5
Blinks green
Lights up green
–-
–-
–-
–-
6
–- –-
Lights
up
green
Lights
up red
Blinks green –-
7
Lights up red
Blinks red
–-
–-
Lights up
green
Blinks green
REFERENCE
Further information regarding the functionality of the handy controller you find
in the operation manual for the handy controller or see page 84.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG