SF4C Safety light curtain
2.4 Protection Area
23
!
DANGER!
Refer to the examples of sensor placement as follows and
understand them thoroughly before installing the sensors.
Improper sensor placement could cause the sensor to
malfunction, which may result in serious injury or death.
If this device is used in multiple sets, arrange them so that
mutual interference is avoided. If mutual interference occurs,
it can result in serious injury or death.
EXAMPLE
1) Install the emitters or the receivers back to
back.
Receiver
Receiver
Emitter
Emitter
2) Arrange the emitters and the receivers
vertically on opposite sides.
Receiver
Receiver
Emitter
Emitter
3) Arrange the emitters and the receivers
horizontally on opposite sides.
Receiver
Receiver
Emitter
Emitter
4) Install a barrier
Receiver
Barrier
Receiver
Emitter
Emitter