12
Item
Unit
Refrigerant System
Fan
Type
Propeller Fan
Material
PP
Motor Type
DC (8-poles)
Output Power
W
60
Fan Speed
rpm
Cooling: 680 (Top), 720 (Bottom)
Heating: 630 (Top), 670 (Bottom)
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 51 x 19
Size (W x H X L)
mm
44 x 1295.4 x 898.8:864.3
Item
Unit
Mono bloc Unit
Dimension
Height
mm (inch)
1410 (55-17/32)
Width
mm (inch)
1283 (50-17/32)
Depth
mm (inch)
320 (12-5/8)
Net Weight
kg (lbs)
150 (331)
Noise Level
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
dB(A)
Cooling: 55
Heating: 55
-
Power level dB
Cooling: 72
Heating: 72
Heating: 66
-
Power Source (Phase, Voltage, Cycle)
Ø
Three
V
400
Hz
50
Input Power
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
kW
Cooling: 5.11
Heating: 3.54
Heating: 5.16
Maximum Input Power for Heatpump System
kW
11.02k
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
3Ø / 16.4 / 11.02k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
3Ø / 13.0 / 9.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
- / - / -
Starting current
A
7.7
Running Current
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
A
Cooling: 7.6
Heating: 5.3
Heating: 7.7
Maximum Current for Heatpump System
A
16.4
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
%
Cooling: 97
Heating: 97
Heating: 97
Power Cord
Number of core
-
Length
m (ft)
-
Thermostat
Electronic Control
Protection Device
Electronic Control