Note
•
The upside-down function is available when <Ceiling> is selected for “Image capture mode”.
(
•
When “Fisheye” is selected for “Image capture mode”, images are not turned upside-down.
[Indicator]
Determine whether or not to use the following indicators. Select “On” to use the following indicators to check
the operational status by lighting them. Select “Off” to turn off the indicators at all times.
–
Link indicator (LINK)
–
Access indicator (ACT)
–
SD memory card error indicator/ABF indicator (SD ERROR/ABF)
–
SD MOUNT indicator (SD MOUNT)
•
Default:
On
Note
•
Link indicator (LINK) (orange):
This indicator will light when communication with the connected
device is available.
•
Access indicator (ACT) (green):
This indicator will blink when accessing a network.
•
SD memory card error indicator/ABF indicator (SD ERROR/ABF) (red):
Lights when an error
occurred in the SD memory card. This LED will blink about once a second in the process of the auto
back focus function, and blinking will stop when the focus adjustment is complete. Except when the
auto back focus is being used, when the indicator blinks, it indicates that an error occurred in the SD
memory card.
•
SD MOUNT indicator (SD MOUNT) (green):
Lights when data can be saved to the SD memory card.
It blinks or is off when data cannot be saved to the SD memory card.
–
Indicator is off:
Indicates “Not use” is selected for SD memory card, or an error occurred for the
SD memory card.
–
Indicator blinks:
Indicates the SD memory card is being recognized or is performing the necessary
processing for the SD memory card to be removed.
–
Indicator lights:
Indicates data can be saved to the SD memory card.
[Alarm status update mode]
Select an interval of the camera status notification from the following.
When the status of the camera changes, the alarm occurrence indication button, the [AUX] button or the SD
saving status indicator will be displayed to notify of the camera status.
•
Polling(30s):
Updates the status each 30 seconds and provide notification of the camera status.
•
Real time:
Provide notification of the camera status when the status has changed.
•
Default:
Real time
Note
•
Depending on the network environment, notification may not be provided in real time.
•
When multiple cameras are using the same “Alarm status reception port”, even if “Real time” is selected
for “Alarm status update mode”, status notification is not provided in real time. In this case, change the
“Alarm status reception port” settings.
[Alarm status reception port]
When selecting “Real time” for “Alarm status update mode”, designate a port number to which the status change
notification is to be sent.
•
Available port number:
1 - 65535
•
Default:
31004
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
Operating Instructions
65
10 Configure the basic settings of the camera [Basic]