Note
•
When “On” is selected, notification of the alarm occurrence will be provided to the registered destination
server addresses in order (to IP address 1 first, to IP address 8 last).
[Additional alarm data]
Determine whether or not to send notifications for VMD alarm detection area numbers with the Panasonic
alarm protocol by selecting On/Off.
•
Default:
Off
[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
•
Available range:
1 - 65535
•
Default:
1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
[Retry times]
Select a retry time for the Panasonic alarm protocol.
•
Available range:
0-30
•
Default:
2
Destination of notification
[Address 1] - [Address 8]
Enter the destination IP address or host name of the Panasonic alarm protocol from the following. Up to 8
destination server addresses can be registered.
•
[Alarm] checkbox:
When the checkbox is checked, the Panasonic alarm notification will be provided upon
an alarm occurrence.
•
[Diag.] checkbox:
When the checkbox is checked, notification using Panasonic alarm protocol will be
provided in the following cases.
–
When notification of the remaining capacity of the SD memory card has been provided
–
When the SD memory card has become full
–
When the SD memory card cannot be recognized
•
[Destination server address]:
Enter the destination server address or host name.
–
Available characters:
Alphanumeric characters, the colon (:), the period (.), the underscore (_), and
the hyphen (-).
To delete the registered destination server address, click the [Delete] button respective to the desired
destination server address.
[Notification per VMD area]
Select “On” or “Off” to determine whether or not to set “Notification per VMD area”.
If “Notification per VMD area” is turned “On”, an alarm is notified only when “Alarm area No.” matches “Alarm
area” configured by “VMD alarm”. Alarm notifications other than “VMD alarm” are not implemented. When
using “Notification per VMD area”, select “On” for “Status” of the alarm area in VMD.
•
Default:
Off
[Alarm area No.]
•
Available range:
1-4
•
Default:
1
136
Operating Instructions
13 Configure the alarm settings [Alarm]