2
1
4
3
5
6
8
7
1 [LAMP POWER]
Selects the [LAMP POWER] setting.
2 [AUTO POWER SAVE]
Sets to [ON] when setting [SIGNAL DETECTION] and [AV
MUTE DETECTION].
3 [AMBIENT LIGHT DETECTION]
Selects to enable ([ON])/disable ([OFF]) the environmental
luminance interlock function.
4 [SIGNAL DETECTION]
Selects to enable ([ON])/disable ([OFF]) the no signal interlock
function.
5 [AV MUTE DETECTION]
Selects to enable ([ON])/disable ([OFF]) the AV MUTE detection
function.
6 [POWER MANAGEMENT]
Selects the power consumption mode.
7 [TIMER]
Selects the time that the lamp is turned off when the POWER
MANAGEMENT function is using.
8 [Submit]
Updates the settings.
Note
f
For details of each setting item, refer to the [PROJECTOR SETUP] menu
→
[ECO MANAGEMENT] (
x
page 73) on the projector.
[E-mail set up] page
When there is a problem or the runtime of a luminous lamp reaches a set value, an E-mail can be sent to preset
E-mail addresses (up to two addresses).
Click [Detailed set up]
→
[E-mail set up].
1
2
3
4
5
6
1 [ENABLE]
Select [Enable] to use the E-mail function.
2 [SMTP SERVER NAME]
Enter the IP address or the server name of the E-mail server
(SMTP). To enter the server name, the DNS server needs to be
set up.
3 [MAIL FROM]
Enter the E-mail address of the projector. (Up to 63 characters
in single byte)
4 [MEMO]
Enter information such as the location of the projector that
notifies the sender of the E-mail. (Up to 63 characters in single
byte)
5 [MINIMUM TIME]
Change the minimum interval for the temperature warning
E-mail. The default value is 60 minutes. In this case, another
E-mail will not be sent for 60 minutes after sending the
temperature warning E-mail even if it reaches the warning
temperature.
6 [INTAKE AIR TEMPERATURE]
Change the temperature setting for the temperature warning
mail. A temperature warning E-mail is sent when the
temperature exceeds this value.
ENGLISH
-
103
Chapter 5 Operation of Function - Web control function