![Panasonic PT-VW360D Operating Instructions Manual Download Page 99](http://html1.mh-extra.com/html/panasonic/pt-vw360d/pt-vw360d_operating-instructions-manual_4718704099.webp)
Error information page
When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the
[Projector status]
screen, click it to display the error/warning details.
f
The projector may go into the standby status to protect the projector depending on the contents of the error.
1
PT-VW360D
000000000
1 Self-diagnosis result display
Displays the item check results.
[OK]:
Indicates that operation is normal.
[FAILED]:
Indicates that there is a problem.
[WARNING]:
Indicates that there is a warning.
r
[FAILED] items displayed when a problem occurs
Parameter
Description
[FAN]
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
[FAN(INTAKE)]
Trouble has occurred in the intake fan.
[FAN(LAMP)]
Trouble has occurred in the luminous lamp cooling fan.
[FAN(EXHAUST)]
Trouble has occurred in the exhaust fan.
[INTAKE AIR TEMPERATURE]
The air intake temperature is too high. The projector may be used in an operating environ-
ment where the temperature is high, such as near a heating appliance.
[EXHAUST AIR TEMPERATURE]
The exhaust air temperature is high. The air exhaust port may be blocked.
[OPTICS MODULE TEMPERATURE]
The temperature around the optics module inside the projector is high. The projector may
be used in an operating environment where the temperature is high, such as near a heating
appliance.
[LAMP REMAIN TIME]
The luminous lamp runtime has exceeded the prescribed cumulative time, and it is now time
to replace the luminous lamp.
[LAMP STATUS]
The luminous lamp has failed to light.
Wait a short while for the luminous lamp to cool off, and then turn on the power.
[APERTURE (CONTRAST-SHUTTER)]
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
[INTAKE AIR TEMP.SENSOR]
Trouble has occurred in the sensor used to detect intake air temperature. Consult your
dealer.
[OPTICS MODULE SENSOR]
Trouble has occurred in the optics module sensor. Consult your dealer.
[EXHAUST AIR TEMP.SENSOR]
Trouble has occurred in the sensor used to detect exhaust air temperature. Consult your
dealer.
[AIR FILTER]
There is too much dust accumulated in the air filter unit. Turn off the projector and unplug the
power plug from the wall outlet, then replace the air filter unit.
[COVER OPEN]
The cover is open.
[Network status] page
Click [Status]
→
[Network status].
The current network setting status is displayed.
ENGLISH
-
99
Chapter 5 Operation of Function - Web control function