9. Attention
・
If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command
may not be executed. Try sending or receiving any command after 60 seconds.
・
When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response
from the projector before sending the next command.
・
It might take time by the time the response returns because the command is processed in the projector.
Set the time-out to 10 seconds or longer.
・
When multiple projectors are all controlled
1) Set a different ID for each projector
2) Set [RESPONSE(ID ALL)] to [ON] in only one projector
3) Set [RESPONSE(ID ALL)] to [OFF] for all other projectors set in Step 2)
・
When multiple projectors are all controlled by group unit
1) Set a different ID for each projector
2) Set [RESPONSE(ID GROUP)] to [ON] in only one projector
3) Set [RESPONSE(ID GROUP)] to [OFF] for all other projectors set in Step 2)
4. 2. Control through LAN terminal
Connection and command transmission changes depending on mode (admin password is set or not with web control).
Control according to the procedure in "4.2.2" on the protection mode (the password is set), and according to the
procedure in "4.2.3" on the unprotected mode (the password is not set).
4. 2. 1. Connection example
4. 2. 2. When Web control administrator rights password is set (Protect mode)
4. 2. 2. 1. Connecting
1. Obtain the IP address and port number (Initial setting value = 1024) of the projector and request for a connection
to the projector.
You can obtain both the IP address and the port number from the menu screen of the projector.
・
: Obtain from the main menu
→
[NETWORK]
→
[NETWORK STATUS]
・
: Obtain from the main menu
→
[NETWORK]
→
[NETWORK CONTROL]
→
[COMMAND PORT]
2. Check the response from the projector
・
Response data
Mode: 1 = Protect mode
3. Generate a 32-byte hash value from the following data using MD5 algorithm.
Administrator rights user name for Web control (default user name is “admin1”)
Password of above administrator rights user (default password is “panasonic”)
8-byte random number obtained in Step 2)
: colon : Separator
‘1’
IP address
Port number
1 byte
1 byte
“zzzzzzzz”
8 bytes
(ASCII string)
Note: Lan cable and Hub are not standard accessories.
When connected directly, cross type cable is
recommended.
Termination symbol
Data section
Blank
Mode
Blank
Random number section
“NTCONTROL”
‘ ’
(CR)
9 bytes
1 byte
xxxxxx
‘ ’
Possible to control this projector by connecting PC to the LAN terminal on the side of this projector.
0x20
0x31
0x20
0x0d
(ASCII code hexadecimal number)
1 byte
Summary of Contents for PT-DZ13KU
Page 6: ...6 2 Specifications 2 1 Specifications The specifications of the projector are as follows...
Page 8: ...8 2 3 Terminal...
Page 9: ......
Page 11: ...INF 2 1 The name of each part 1 1 Projector body Front Rear Si Bottom...
Page 12: ...INF 3 1 2 Control panel 1 3 Connecting terminals...
Page 13: ...INF 4 1 4 Remote control Front Top Si Bottom...
Page 14: ...INF 5 2 Menu Navigation...
Page 15: ...INF 6...
Page 16: ...INF 7...
Page 17: ...INF 8...
Page 35: ...INF 26 5 Select Log SYSTEM and click Get button 6 Log is displayed...