Installation/Troubleshooting
38
4.
Roll up putty around the cables and fit them into the holes to prevent water
from getting inside the camera.
Notes
•
Confirm the camera is functioning before puttying the cables. Putties and
self bonding tape cannot be used twice.
•
Check the length and the type of the Ethernet cable before fixing with
putty.
5.
Cover the putty by rolling.
•
Self bonding tape is used to fix the cables in a mount. Keep at least 20 cm
(about 8 inches) of it for cable fixing.
6.
Connect the Ethernet cable to the Ethernet port of hub, router and PC.
Push the putty
into the connector
cover.
Three putties
Cover the connector cover
and cables with the last
putty, and fix the shape.
5 –10 mm
(0.2–0.4 inches)
Do not cover
the ventilation hole.