Download Timing
Explanation
At a specified time each day
After the unit is powered on, it will check for and download configuration
files once per day at the specified time.
SIP Phone
Provisioning
Server
02:00
02:00
Power On
at 12:00
Check
Download
Check
Download
Check
Download
CFG_RESYNC_TIME="02:00"
The configuration files are downloaded at a set time each day:
•
Set a time by specifying "
CFG_RESYNC_TIME
".
Note
•
If the value for "
CFG_RESYNC_TIME
" is any valid value other
than an empty string, the unit downloads the configuration files
at the fixed time, and the settings specified in "
CFG_CYCLIC
",
"
CFG_CYCLIC_INTVL
", and "
CFG_RTRY_INTVL
" are
disabled.
•
The time is specified using a 24-hour clock ("00:00" to "23:59").
When directed
When a setting needs to be changed immediately, units can be directed to
download the configuration files by sending them a NOTIFY message that
includes a special event from the SIP server.
•
In the configuration file:
–
Specify the special event text in "
CFG_RESYNC_FROM_SIP
".
•
In the Web user interface:
–
Click the
[Maintenance]
tab, click
[Provisioning Maintenance]
,
and then enter the special event text in
[Header Value for Resync
Event]
.
Generally, "check-sync" or "resync" is set as the special event text.
42
Administrator Guide
Document Version 2012-06
2.2.4 Downloading Configuration Files
Summary of Contents for KX-UT248-B
Page 32: ...32 Administrator Guide Document Version 2012 06 1 2 2 Firmware Update ...
Page 282: ...282 Administrator Guide Document Version 2012 06 6 3 1 Flexible Button Settings ...
Page 286: ...286 Administrator Guide Document Version 2012 06 7 4 Local Firmware Update ...
Page 292: ...292 Administrator Guide Document Version 2012 06 8 1 Troubleshooting ...
Page 293: ...Section 9 Appendix Document Version 2012 06 Administrator Guide 293 ...
Page 297: ...Index Document Version 2012 06 Administrator Guide 297 ...
Page 305: ...Document Version 2012 06 Administrator Guide 305 Notes ...