CFG_RESYNC_DURATION
Value Format
Integer
Description
Specifies the time period, in minutes, added to "
CFG_RESYNC_TIME
"
to create a range within which the unit checks for updates of
configuration files. The check will be performed at a random time within
this range.
Value Range
0–1439
Default Value
0
CFG_RESYNC_FROM_SIP
Value Format
String
Description
Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range
Max. 15 characters
Note
•
An empty string is not allowed.
Default Value
check-sync
Web User Interface Reference
Header Value for Resync Event (Page 150)
5.3.6 Management Server Settings
ACS_URL
Value Format
String
Description
Specifies the URL of the Auto-Configuration Server for using TR-069.
Note
•
This parameter must be in the form of a valid HTTP or HTTPS
URL, as defined in RFC 3986.
Value Range
Max. 256 characters
Default Value
Empty string
Web User Interface Reference
Management Server URL (Page 151)
ACS_USER_ID
Value Format
String
Description
Specifies the user ID for the Auto-Configuration Server for using
TR-069.
184
Administrator Guide
Document Version 2012-06
5.3.6 Management Server Settings
Summary of Contents for KX-UT248-B
Page 32: ...32 Administrator Guide Document Version 2012 06 1 2 2 Firmware Update ...
Page 282: ...282 Administrator Guide Document Version 2012 06 6 3 1 Flexible Button Settings ...
Page 286: ...286 Administrator Guide Document Version 2012 06 7 4 Local Firmware Update ...
Page 292: ...292 Administrator Guide Document Version 2012 06 8 1 Troubleshooting ...
Page 293: ...Section 9 Appendix Document Version 2012 06 Administrator Guide 293 ...
Page 297: ...Index Document Version 2012 06 Administrator Guide 297 ...
Page 305: ...Document Version 2012 06 Administrator Guide 305 Notes ...