System
70
Programming Guide
Parameter
Switching Day / Night Mode
Default
Disable
Value Range
1.
Enable
2.
Disable
Description/Function
Enables or disables switching the Day / Night / Lunch / Break
service on a Class of Service (COS) basis.
Reference
• 1.3 System Features (F/G)
– Night Service
• 2.11.4 Switching the Day/Night Service (U/M)
Parameter
Call from TRS Level 7 Extension
Default
Enable
Value Range
1.
Enable
2.
Disable
Description/Function
If set to "Enable," TRS level 7 extension users can call the
extensions with this COS level.
Reference
• 1.6 Originating Features (F/G)
– Toll Restriction
Parameter
Time Limit of Outside Calls
Default
No
Value Range
1.
Yes
2.
No
Description/Function
Specifies whether to restrict the duration of outside calls or not.
Notes
•
If set to "Yes," the system disconnects a CO call originated
or answered by the programmed extension user when the
time specified by "Extension-to-CO Line Call Duration
Time (1-64 min)" in Section "2.5
System Timer" expires.
•
This setting may apply to "Outgoing CO call only" or "Both
incoming and outgoing CO calls" depending on "5. Limited
call duration" setting in Section "2.8
Reference
None
Summary of Contents for KX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration...
Page 38: ...Configuration 38 Programming Guide...
Page 39: ...System Programming Guide 39 Section 2 System...
Page 121: ...Group Programming Guide 121 Section 3 Group...
Page 122: ...Group 122 Programming Guide 3 1 Group Used to assign various group parameters...
Page 166: ...Group 166 Programming Guide...
Page 167: ...Line Programming Guide 167 Section 4 Line...
Page 169: ...Line Programming Guide 169 4 2 Trunk Line Used to assign various parameters for trunk lines...
Page 240: ...Line 240 Programming Guide...
Page 241: ...Features Programming Guide 241 Section 5 Features...
Page 285: ...Toll Restriction Programming Guide 285 Section 6 Toll Restriction...
Page 291: ...ARS Automatic Route Selection Programming Guide 291 Section 7 ARS Automatic Route Selection...
Page 300: ...ARS Automatic Route Selection 300 Programming Guide...
Page 301: ...Private Network Programming Guide 301 Section 8 Private Network...
Page 305: ...DDI DID Programming Guide 305 Section 9 DDI DID...
Page 313: ...Maintenance Programming Guide 313 Section 10 Maintenance...
Page 339: ...Programming Error Messages Programming Guide 339 Section 11 Programming Error Messages...
Page 356: ...Programming Error Messages 356 Programming Guide...
Page 357: ...Default Values Programming Guide 357 Section 12 Default Values...