Group
Programming Guide
127
Parameter
Line Hunting Order
Default
Normal
Value Range
1.
Normal
2.
Reverse
3.
Sequential
Description/Function
Specifies the hunting sequence of idle lines on a trunk group basis.
1.
Normal:
The system connects the user to an idle trunk line with the
lowest physical number.
2.
Reverse:
The system connects the user to an idle trunk line with the
highest physical number.
3.
Sequential:
To avoid repeated use of the same trunk line, rotation is
performed in numerical order (from the lowest to the highest
trunk port physical number.) Busy lines are skipped, of course.
Reference
• 2.8
System Option (P/G)
– Trunk hunting mode
Parameter
Tenant No.
Default
1
Value Range
1-8
Description/Function
Specifies the tenant (1-8) to which the trunk group is assigned.
(This setting is required when "Tenant Service" is employed.)
Reference
• 1.3 System Features (F/G)
– Tenant Service
• 2.2
Tenant (P/G)
Summary of Contents for KX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration...
Page 38: ...Configuration 38 Programming Guide...
Page 39: ...System Programming Guide 39 Section 2 System...
Page 121: ...Group Programming Guide 121 Section 3 Group...
Page 122: ...Group 122 Programming Guide 3 1 Group Used to assign various group parameters...
Page 166: ...Group 166 Programming Guide...
Page 167: ...Line Programming Guide 167 Section 4 Line...
Page 169: ...Line Programming Guide 169 4 2 Trunk Line Used to assign various parameters for trunk lines...
Page 240: ...Line 240 Programming Guide...
Page 241: ...Features Programming Guide 241 Section 5 Features...
Page 285: ...Toll Restriction Programming Guide 285 Section 6 Toll Restriction...
Page 291: ...ARS Automatic Route Selection Programming Guide 291 Section 7 ARS Automatic Route Selection...
Page 300: ...ARS Automatic Route Selection 300 Programming Guide...
Page 301: ...Private Network Programming Guide 301 Section 8 Private Network...
Page 305: ...DDI DID Programming Guide 305 Section 9 DDI DID...
Page 313: ...Maintenance Programming Guide 313 Section 10 Maintenance...
Page 339: ...Programming Error Messages Programming Guide 339 Section 11 Programming Error Messages...
Page 356: ...Programming Error Messages 356 Programming Guide...
Page 357: ...Default Values Programming Guide 357 Section 12 Default Values...