System
118
Programming Guide
Parameter
62. End of Pulsing (End of Identification) Signal
Default
None
Value Range
1.
None
2.
1-15
Description/Function
Specifies the pulse dialling signal after the inter-digit timer expires.
(Assignable only when "DR2" is specified in "Channel Type"
programming and "MFC-R2" is specified in "Receiver Type"
programming in Section "1.6 E1 Port Assignment.")
Note
•
If "None" is specified, the end of pulse dialling signal is not
sent to the Central Office.
Reference
None
Parameter
63. Tenant Select Mode for DID / DDI
Default
Trunk Group
Value Range
1.
Trunk Group
2.
DID / DDI No.
Description/Function
Specifies whether to enable or disable the tenant assigned on a DID
/ DDI No. basis. If "Trunk Group" is selected, then the tenant no.
works for the CO lines belonging to the Trunk Group.
Reference
• 9.2 Number Transformation (P/G)
Parameter
65. Alert Ringing
Default
Disable
Value Range
1.
Disable
2.
Enable
Description/Function
Specifies whether or not to alert the alert extension when the
extension user does not respond to the Timed Reminder (wake-up
call).
Reference
• 1.8 Ringing Features (F/G)
– Timed Reminder (Wake-Up Call)
– Timed Reminder, Remote (Wake-Up Call)
• 2.7.1 Setting the Alarm (Timed Reminder (Wake-Up Call)) (U/
M)
• 3.1.1 Setting the Alarm for Other Extensions (Remote Timed
Reminder (Wake-Up Call)) (U/M)
• 2.2
Tenant (P/G)
– Alert Extension – Day / Night
Summary of Contents for KX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration...
Page 38: ...Configuration 38 Programming Guide...
Page 39: ...System Programming Guide 39 Section 2 System...
Page 121: ...Group Programming Guide 121 Section 3 Group...
Page 122: ...Group 122 Programming Guide 3 1 Group Used to assign various group parameters...
Page 166: ...Group 166 Programming Guide...
Page 167: ...Line Programming Guide 167 Section 4 Line...
Page 169: ...Line Programming Guide 169 4 2 Trunk Line Used to assign various parameters for trunk lines...
Page 240: ...Line 240 Programming Guide...
Page 241: ...Features Programming Guide 241 Section 5 Features...
Page 285: ...Toll Restriction Programming Guide 285 Section 6 Toll Restriction...
Page 291: ...ARS Automatic Route Selection Programming Guide 291 Section 7 ARS Automatic Route Selection...
Page 300: ...ARS Automatic Route Selection 300 Programming Guide...
Page 301: ...Private Network Programming Guide 301 Section 8 Private Network...
Page 305: ...DDI DID Programming Guide 305 Section 9 DDI DID...
Page 313: ...Maintenance Programming Guide 313 Section 10 Maintenance...
Page 339: ...Programming Error Messages Programming Guide 339 Section 11 Programming Error Messages...
Page 356: ...Programming Error Messages 356 Programming Guide...
Page 357: ...Default Values Programming Guide 357 Section 12 Default Values...