Line
178
Programming Guide
Parameter
Start Signal Type
Default
Wink
Value Range
1.
Immediate
2.
Wink
Description/Function
Specifies the start signal type for a DID trunk and a TIE (E&M)
trunk.
1.
Immediate:
The system sends the dialling digits to CO after waiting for the
time length determined by "First Dial Timer" in "Card
Properties" screen of the corresponding trunk card.
For information on "Card Properties" screen, please refer to
"Card Type" in Section "1.2
2.
Wink:
The system sends the dialling digits to CO after receiving the
wink signal.
Reference
• 3.1 TIE Line Features (F/G)
– TIE Line Service
Parameter
Answer Wait Timer
Default
None
Value Range
1.
None
2.
1 min
3.
2 min
4.
3 min
5.
4 min
Description/Function
Specifies the length of time in minutes the system waits, after an
outgoing CO call is made, before the other party answers the call.
If the call is not answered before this timer expires, the call will be
disconnected automatically.
(Assignable only when E1 / ELCOT / RCOT / T1 [TIE / DID] /
DID-2W / DID-MFC / BRI / PRI23 / PRI30 card is installed in the
system.)
Reference
None
Summary of Contents for KX-TD500
Page 5: ...Configuration Programming Guide 5 Section 1 Configuration...
Page 38: ...Configuration 38 Programming Guide...
Page 39: ...System Programming Guide 39 Section 2 System...
Page 121: ...Group Programming Guide 121 Section 3 Group...
Page 122: ...Group 122 Programming Guide 3 1 Group Used to assign various group parameters...
Page 166: ...Group 166 Programming Guide...
Page 167: ...Line Programming Guide 167 Section 4 Line...
Page 169: ...Line Programming Guide 169 4 2 Trunk Line Used to assign various parameters for trunk lines...
Page 240: ...Line 240 Programming Guide...
Page 241: ...Features Programming Guide 241 Section 5 Features...
Page 285: ...Toll Restriction Programming Guide 285 Section 6 Toll Restriction...
Page 291: ...ARS Automatic Route Selection Programming Guide 291 Section 7 ARS Automatic Route Selection...
Page 300: ...ARS Automatic Route Selection 300 Programming Guide...
Page 301: ...Private Network Programming Guide 301 Section 8 Private Network...
Page 305: ...DDI DID Programming Guide 305 Section 9 DDI DID...
Page 313: ...Maintenance Programming Guide 313 Section 10 Maintenance...
Page 339: ...Programming Error Messages Programming Guide 339 Section 11 Programming Error Messages...
Page 356: ...Programming Error Messages 356 Programming Guide...
Page 357: ...Default Values Programming Guide 357 Section 12 Default Values...