3-44
Features
P
3
Features
☞
Preferred Line Assignment — Incoming
A proprietary telephone user can select the method to answer incoming outside calls from
the following 3 line preferences. System Programming and Proprietary Telephone Settings
are required.
No Line Preference:
When an incoming call is received, the extension user must go
off-hook and then press the flashing CO button.
Prime Line Preference:
When incoming calls are received at the same time, the user
can receive the call on the preferred outside (CO) line by only
going off-hook.
Ringing Line Preference: When an incoming call is received, the user can receive the
call ringing at their telephone by going off-hook.
• A single line telephone can only set “Ringing Line Preference”.
• Line access button(s) (Single-CO, Other-CO or Group-CO) should be assigned to CO
button(s) beforehand.
• Required System Programming
[408]–[410] Flexible Ringing Assignment — Day/Night/Lunch
[411]–[413] Delayed Ringing Assignment — Day/Night/Lunch
• Related Feature Reference
Line Access Buttons
• Operating Instructions References
1.2 Proprietary Telephone Settings, “Customizing Your Telephone Functions”,
Preferred Line Assignment — Incoming
1.2 Proprietary Telephone Settings, “Customizing the Buttons on Your Telephone”,
Line Access Buttons
☞
!
!
Power Failure Transfer
During a power failure, specific extension telephones are automatically connected to specific
outside (CO) lines. This provides outside (CO) line conversations between the following
extensions and outside (CO) lines.
Outside (CO) line 1 : extension jack 01
Outside (CO) line 4 : extension jack 09
A single line telephone (SLT) can work in case of a power failure. Connect an SLT to the
above extension jack. For more information, refer to the Operating Instructions.
• All other conversations, except the above combinations, are disconnected during a power
failure.
• Only an outside (CO) line can have a conversation. All other features do not work.
• We recommend connecting a single line telephone (SLT) in parallel at extension jacks 01
and 09, so that an SLT can be used during a power failure.
• Connection Reference
2.19 Auxiliary Connection for Power Failure Transfer
• Related Feature Reference
Paralleled Telephone Connection
• Operating Instructions Reference
1.7 Useful Features, “Power Failure Transfer”
!
!
Summary of Contents for KX-TA616
Page 13: ...Section 1 Basic System Construction ...
Page 16: ...1 4 Basic System Construction ...
Page 17: ...Section 2 Installation ...
Page 51: ...Section 3 Features ...
Page 118: ...3 68 Features ...
Page 119: ...Section 4 System Programming ...
Page 200: ...4 82 System Programming ...
Page 201: ...Section 5 Appendix ...
Page 209: ...Section 6 TroubleShooting ...
Page 213: ...Section 7 Programming Tables ...
Page 243: ...Memo ...
Page 244: ...Memo ...