(3)
When noise equipment is connected to distribution board
These are examples using Japanese power line and distribution board.
If PLC 1 and PLC 2 can not communicate (influence PLC link) due to the influence of noise
equipment connected to distribution board B, installing (inserting) a noise filter in the sub breaker to
which the noise equipment is connected will often cause noise to decrease, and you can
communicate. (Noise equipment examples: fan motor, inverter, etc.)
In addition, when there are two main trunks (main breakers) in the distribution board, if PLC 2
connected to one with more noises can not communicate with PLC 1 in distribution board A,
change the connection beyond the main trunk with less noise. There are many times that noise will
be reduced and communication becomes possible.
Influence of noise equipment
Noise equipment
-Inverter
-Ventilating fan
-Motor etc.
Installing a noise filter
A lot of noise equipment
Noise equipment
is little
Branch is little
Select noise less
environment
Distribution board A
Distribution board B
Distribution board A
Distribution board B
Summary of Contents for HD-PLC DA-PU100
Page 1: ...Administrator s Manual PLC Adaptor Model No DA PU100 ...
Page 4: ...DA PU100 Series Administrator s Manual 4 Chapter 1 Introduction ...
Page 9: ...DA PU100 Series Administrator s Manual 9 Chapter 2 Installation and Operation ...
Page 25: ...DA PU100 Series Administrator s Manual 25 Chapter 3 PC Tools ...
Page 32: ...DA PU100 Series Administrator s Manual 32 Chapter 4 Preparation for Operation ...
Page 58: ...DA PU100 Series Administrator s Manual 58 Chapter 5 Troubleshooting ...
Page 62: ...DA PU100 Series Administrator s Manual 62 Chapter 6 Specifications ...
Page 65: ...DA PU100 Series Administrator s Manual 65 7 Dimensions With the fixing brackets attached ...