Caution:
The OPC Drum is sensitive to light. To prevent
optical exposure problems, do not expose the
OPC Drum to direct sunlight or bright light (even if
it is a 1000-Lux fluorescent lamp).
(7) Cover the Drum with 2 sheets of white paper as
illustrated.
(8) Remove 3
Split Lock Washers
(1825).
(9) Remove 3
Separators
(1826) by unhooking the
spring as illustrated.
Note:
When installing the Separators, hook the springs
by using a Tweezer or a Small Screw Driver.
<Removing the Old
OPC Drum
>
(10) Remove 1
Screw
(21).
(11) Remove the
Corona Unit
(1851).
(See steps (20 ~ 23), for cleaning instructions)