356
JAN 2006
Ver. 5.2
DP-3510/3520/3530/4510/4520/4530/6010/6020/6030
<For Letter-R Setting>
(30) Reinstall the Sensor Assy at the
Letter-R
position.
(31) Secure with 1 Screw.
<For Legal Setting>
(32) Open the Door (Large).
(33) Remove the Harness from the bottom Clamp.
(34) Reinstall the Sensor Assy at the
Legal
position.
(35) Secure with 1 Screw.
(36) Reinstall the Top Cover.
(37) Reinstall the Front Cover.
(38) Attach the Paper Size Label as illustrated.
Note:
See Installation Instructions of the LCT for
adjusting LCT label.
(39) Plug the AC Power Cord into the wall outlet and
turn the Main Power Switch on the Back and the
Power Switch on the Left Side of the machine to
the ON position.