Page 1-37
REGULAR
MAINTENANCE
1
Check Every 140 Hours (Once a Week)
444C-E-MMA01-A05-04
444C-406E
444C-421P
Nozzle holder
Spring for clamp
arm holder
Clamp arm
Nozzle
444C-422P
7.
Checking the nozzle arrangement and setting the nozzle
a. Setting the nozzle to the nozzle holder
1.
Set the nozzle to the nozzle holder.
∗
Hold the edge of the nozzle reflector and push
it upward the nozzle holder.
∗
The clamp arm may be taken off by pushing
the nozzle sideways.
6.
Cleaning the holder of the transfer head
1.
Clean the fixing groove (which is
reverse L-shaped) on the transfer
head with a swab.
2.
Wipe the circumference of the tip of
the guide shaft section on the nozzle
holder with a cloth.
∗
Use a lint-free cloth.
Fixing groove
Guide shaft of nozzle holder
444C-517P