Page 1-77
REGULAR
MAINTENANCE
1
444C-E-MMA01-A09-05
Check Every 6000 Hours (Once a Year)
3.
Press Address .
4.
Display “63. AstFront tape cutter
Open”, and turn it ON.
∗
If the cover of the cutter parts is not closed, it is
impossible to operate. (No.64 should be OFF)
5.
Release the air pressure inside the
machine.
Close the main air valve.
Pull up the regulator knob, and turn it to the left
until it stops.
Make sure the exhaust sound disappears and
the gauge shows 0 MPa.
Lock the valve lever. A worker should carry the
key. (DU/DHU only)
4H4C-513P
444C-EEn-MaOc-015
To the next page
4
1
2
3