Page 1-88
444C-E-MMA01-A09-05
Check Every 12000 Hours (Once Two Years)
1-8-2
XY Unit : Replacing (Replacing Kit) the Valve (For Select
ing the Nozzle, For the Cylinder)
The bad motion owing to the abrasion of the valve leads to the bad motion of the cylinder, and
occurs the miss of the picking and mounting. So regular replacement is required.
1.
Turn OFF the power.
2.
Release the main air.
3.
Remove the head cover.
∗
Remove the screw setting the head cover by
using the philips driver.
To the next page
Tools
Philips driver, allen wrench
Required time
30 minutes
REL
EA
SE
TR
IP
O
F
F
ON
RE
S
E
T
444C-436P
444C-437P
Philips driver
Head cover
444C-412E
Screw