25
¢¢
G/L. Color Bar Set
¢¢
H Phase
±0
SC Coarse
1
SC Fine
±0
Color Bar Set
7.5IRE
Return
PAGE
ITEM
UP
DOWN
COARSE
FINE
SC PHASE
270
°
180
°
90
°
0
°
H.PHASE
USER SET
OFF
ENC
VF
ON
Adjustments
$
Genlock adjustment
When multiple cameras are to be used or the camera is to be used in combination with
other equipment, the phase adjustments must be performed using the camera or RCU
(RCB) in order to achieve genlock and bring the phases into alignment. Ask your dealer
to perform it.
Horizontal phase adjustment
Monitor the genlock signal input (black burst signal) and video signal output waveforms
on a dual-trace oscilloscope, and bring the horizontal phase into alignment using the
camera or RCU (RCB).
1
Hold down the NO/BAR switch for at
least 5 seconds or so, and set to color
bar signals.
2
Select “H phase” as the genlock/color
bar setting on the sub-menu.
3
Bring the horizontal phase into
alignment using the YES/ABC switch
or NO/BAR switch.
When performing the adjustment
using the camera
Use the horizontal phase control to
perform the adjustment.
<Note>
When adjusting the horizontal phase from
the RCU (RCB), set the BAR/CAM switch
to BAR before performing the adjustment.
The horizontal phase cannot be adjusted if
this switch is set to CAM. Upon completion
of the adjustment, be absolutely sure to
return the BAR/CAM switch to CAM.
When performing the adjustment
using the RCU (RCB)
Camera
–
+
MENU
ITEM/AWC
YES/ABC
NO/BAR
OPTION CARD
VIDEO OUT
I/F REMOTE
G/L IN
IRIS
DC12V IN
YES/ABC switch
NO/BAR switch
RCU (RCB)
Horizontal phase control
Subcarrier phase coarse
adjustment switch
Subcarrier phase fine
adjustment control
Genlock signal input
(black burst)
Video signal
Adjusting the horizontal phase