36 (E)
ENGLISH
Menu Item Settings and Changes
(in user mode)
P
Electronic shutter step selection [Step: OFF or 1/120 to 1/10000]
This can only be set when “Step” has been selected as the electronic shutter mode
selection
O
setting.
OFF:
The electronic shutter is set to OFF.
1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:
The electronic shutter is actuated at the respective shutter speed.
<Notes>
O
The speed cannot be set to 1/250, 1/2000, 1/4000 or 1/10000 by operating the RCU
(RCB).
O
ELC may not operate when the camera alone is used.
Similarly, it may not work when AUTO has been selected as the RCU (RCB) iris
switch setting.
O
When ELC is set under fluorescent lighting, the flicker may increase.
Q
Electronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz]
This can be set only when “Synchro scan” has been selected as the electronic shutter
mode selection
O
setting.
The horizontal bar noise can be reduced by adjusting the synchro scan frequency when
shooting the screen of a work station, etc.
Refer to the table below for the light quantity that should be set at different shutter
speeds and synchro scan frequencies.
R
CCD readout method selection [Field/Frame: Field, frame1 or frame2]
Field
: Field storage is used as the CCD storage method.
Frame1 : Frame storage is used, and the vertical resolution is improved as a result.
Frame2 : Field storage and the electronic shutter are used, and the vertical resolution is
improved with no accompanying increase in the residual image as a result.
Shutter speed
Synchro scan
frequency
Light quantity
ratio required
OFF
==
1
1/120
120.2 Hz
2
1/250
250.0 Hz
4
1/500
492.2 Hz
8
1/1000
984.4 Hz
16
1/2000
1.969 kHz
32
1/4000
3.938 kHz
64
1/10000
7.875 kHz
160