30 (E)
ENGLISH
5
Auto gain increase selection [Auto Gain Up: OFF, LOW or HIGH]
LOW : The function for automatically increasing the gain up to approximately 18 dB is
activated, and the light quantity is thereby automatically adjusted.
HIGH : The function for automatically increasing the gain up to approximately 30 dB is
activated, and if the light quantity is still insufficient, ‘night eye’ (digital gain
increase) is added, and the light quantity is thereby automatically adjusted.
OFF : The function for automatically increasing the gain is not activated (the gain can
still be increased manually).
<Note>
The auto gain increase function may not be activated when the camera alone is used.
Similarly, it may not be activated when AUTO has been selected as the RCU’s (RCB)
iris switch setting.
6
Manual gain increase selection [Manu Gain Up: 0 dB to 30 dB or N-Eye (night eye)]
This item can be set only when “OFF” has been selected for the auto gain increase
selection
5
setting.
0 dB:
This setting is the one which is normally used.
1 dB to 30 dB:
Use this setting when shooting in dark locations and an adequate video output cannot
be obtained even if the lens iris is opened.
N-Eye:
This increases the sensitivity by adding the digital gain increase to the 30 dB gain
increase.
<Note>
Only “0 dB,” “9 dB” or “18 dB” can be set when the RCU (RCB) is used.
7
Black level adjustment [Pedestal: –30 to +30]
This enables the black level (pedestal) of the luminance (Y) signal to be set. It is used to
align the black level of two or more cameras.
8
Contrast adjustment [Contrast: LOW, MID or HIGH]
This enables the contrast to be set in 3 stages.
9
Chroma level adjustment [Chroma Level: –3 to +3]
This enables the chroma level to be set in ±3 stages.
:
Flesh tone adjustment [Flesh Tone: –3 to +3]
This enables the flesh tones to be set in ±3 stages.