37 (E)
Menu Item Settings and Changes
(in user mode)
S
Gain increase adjustment
[Gain: AGC HIGH, AGC LOW, 0 dB to 30 dB or N-Eye (night eye)]
AGC LOW
:
The function for automatically increasing the gain up to
approximately 18 dB is activated, and the light quantity is
thereby automatically adjusted.
AGC HIGH
:
The function for automatically increasing the gain up to
approximately 30 dB is activated, and if the light quantity is still
insufficient, ‘night eye’ (digital gain increase) is added, and the
light quantity is thereby automatically adjusted.
0 dB :
This setting is the one which is normally used.
1 dB to 30 dB :
Use this setting when shooting in dark locations and an
adequate video output cannot be obtained even if the lens iris is
opened.
N-Eye
:
This increases the sensitivity by adding the digital gain increase
to the 30 dB gain increase.
<Notes>
O
“0 dB,” “9 dB,” “18 dB,” “AGC LOW” and “AGC HIGH” can be set by operating the
RCU (RCB).
O
AGC may not operate when the camera alone is used.
Similarly, it may not work when AUTO has been selected as the RCU (RCB) iris
switch setting.
T
Black level adjustment [Pedestal: –30 to +30]
This enables the black level (pedestal level) of the luminance (Y) signal to be set. It is
used to adjust the black level of two or more cameras.
U
Chroma level adjustment [Chroma Level: –3 to +3]
This enables the chroma level to be set in ±3 stages.
V
White balance selection [White Bal: ATW, AWC A, AWC B, P SET 3200K, P SET 5600K]
ATW:
Automatic operation is performed to ensure that the white balance is attained at
all times.
AWC A, AWC B:
The colour temperature conditions at two locations can be stored in the memory
using A and B.
If the white balance is first set and the camera is then used under identical
conditions, the need to repeat the white balance setting can be obviated by simply
selecting AWC A or AWC B.
The colours can be finely adjusted after executing AWC by using R Gain and B
gain in Painting adjustment
X
or by adjusting the R (red) and B (blue) gain
controls on the RCU (RCB).
P SET 3200K:
The white balance which was adjusted under 3200K lighting is set.
P SET 5600K:
The white balance which was adjusted under 5600K lighting is set.